Command Reference
R&S
®
CMW-KM750/-KM751
115
User Manual 1173.9670.02 ─ 05
Example:
See
Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V2.1.10
Manual operation:
See
"Statistical Overviews and Limit Checks"
FETCh:TDSCdma:MEAS<i>:MEValuation:PVTime:CURRent?
FETCh:TDSCdma:MEAS<i>:MEValuation:PVTime:AVERage?
FETCh:TDSCdma:MEAS<i>:MEValuation:PVTime:MINimum?
FETCh:TDSCdma:MEAS<i>:MEValuation:PVTime:MAXimum?
READ:TDSCdma:MEAS<i>:MEValuation:PVTime:CURRent?
READ:TDSCdma:MEAS<i>:MEValuation:PVTime:AVERage?
READ:TDSCdma:MEAS<i>:MEValuation:PVTime:MINimum?
READ:TDSCdma:MEAS<i>:MEValuation:PVTime:MAXimum?
Return the OFF power measured in the three areas of the defined power vs. time tem-
plate. The results can be retrieved for the current, average, minimum and maximum
power vs. time traces.
A power vs. time trace covers one subframe. The power template is applied to each burst
in this subframe. A burst can comprise one active uplink slot or several adjacent active
uplink slots. So within one subframe there can be up to three bursts, e.g. slot 1, slot 3
and slot 5 or slot1+2, slot 4 and slot 6.
The number of returned values is fixed. For "missing" bursts NCAP values are returned.
The number to the left of each result parameter is provided for easy identification of the
parameter position within the result array.
Return values:
<1_Reliability>
<2_Burst1AB>
<3_Burst1CE>
<4_Burst1FH>
OFF power for the first burst, template areas AB, CE and FH
Range:
-100 dBm to 35 dBm
Default unit: dBm
<5_Burst2AB>
<6_Burst2CE>
<7_Burst2FH>
OFF power for second burst
Range:
-100 dBm to 35 dBm
Default unit: dBm
<8_Burst3AB>
<9_Burst3CE>
<10_Burst3FH>
OFF power for third burst
Range:
-100 dBm to 35 dBm
Default unit: dBm
Example:
See
Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V3.0.11
For additional information concerning syntax elements and returned values refer to
ventions and General Information