1xEV-DO Measurements
R&S
®
CMW-KM8xx/-KS8xx
308
User Manual 1173.9511.02 ─ 12
If the current center frequency (
CONFigure:EVDO:MEAS<i>:RFSettings:
) is valid for this band class, the corresponding channel number
CONFigure:EVDO:MEAS<i>:RFSettings:CHANnel
) is also calculated and set.
See also
This command is only relevant for the standalone scenario. For the combined signal
path scenario, use
CONFigure:EVDO:SIGN<i>:RFSettings:BCLass
Parameters:
<BandClass>
USC | KCEL | NAPC | TACS | JTAC | KPCS | N45T | IM2K |
NA7C | B18M | NA9C | NA8S | PA4M | PA8M | IEXT | USPC |
AWS | U25B | PS7C | LO7C
USC:
BC 0, US-Cellular
KCEL:
BC 0, Korean Cellular
NAPC:
BC 1, North American PCS
TACS:
BC 2, TACS Band
JTAC:
BC 3, JTACS Band
KPCS:
BC 4, Korean PCS
N45T:
BC 5, NMT-450
IM2K:
BC 6, IMT-2000
NA7C:
BC 7, Upper 700 MHz
B18M:
BC 8, 1800 MHz Band
NA9C:
BC 9, North American 900 MHz
NA8S:
BC 10, Secondary 800 MHz
PA4M:
BC 11, European 400 MHz PAMR
PA8M:
BC 12, 800 MHz PAMR
IEXT:
BC 13, IMT-2000 2.5 GHz Extension
USPC:
BC 14, US PCS 1900 MHz
AWS:
BC 15, AWS Band
U25B:
BC 16, US 2.5 GHz Band
PS7C:
BC 18, Public Safety Band 700 MHz
LO7C:
BC 19, Lower 700 MHz
*RST:
USC
Example:
See
Specifying General Measurement Settings
Firmware/Software:
V1.0.10.1
Manual operation:
See
CONFigure:EVDO:MEAS<i>:RFSettings:CHANnel
<Channel>
Selects the channel number. The channel number must be valid for the current band
class, for dependencies see
The corresponding center frequency (
CONFigure:EVDO:MEAS<i>:RFSettings:
) is calculated and set.
This command is only relevant for the standalone scenario. For the combined signal
path scenario, use
CONFigure:EVDO:SIGN<i>:RFSettings:CHANnel
Command Reference