![Rohde & Schwarz CMT82 Service Tips Download Page 2](http://html.mh-extra.com/html/rohde-and-schwarz/cmt82/cmt82_service-tips_1477803002.webp)
No monitor speaker audio? Replace H100 lamp on the front panel just besides INPUT 2. This lamp is inside a
black heat shrinking tube (it does not light up anything, so is it as hour counter for service?). Exact value is so far
unknown, but audio works and the 24 V 20 mA lamp glows very faintly - find out the proper voltage and current,
or use what lamp you have - at your own risk!
If you wish to clear user programming settings from memory, hit "9" "9" "SPEC": the CMT re-boots with factory
settings.
If power supply fails or does not work properly, replace fried electrolytic capacitors.
Rev. 2010-10-24