Change the noisy 24V fan to a stack of two 12V DC PC PSU cooling fans connected electrically in series.
Enclosure top and bottom opens up by removing the 4 screws from 2 blue plastic pieces in the rear corners. Fan
connector in on the bottom side. Mark how it is plugged before disconnecting anything though it's not necessary
here.
 

Replace blown LCD backlight lamps; 3 mm diameter 6 V 120 mA miniature dial lamps (H101 to H108). For
this, loosen Volume and VAR knobs (different size of hex screws) and remove knobs, remove also front metal
face plate's 4 screw at corners, 2 small ones between LCDs in the middle and fold mask plate off. Next unscrew
two M2.4 screws by the N- RF input connector, the ones holding the unit (see picture: marked with red squares),
until it also folds out from top. If possible, do the lamp soldering without unplugging the 3 flat cables, the blue
socket's pins are a bit fragile. If the front panel keys do not work after units is reassembled, you probably have
accidentally pulled out (partially) one of the flat cable sockets, possibly from under (rear) the unit at the other end
of the cable. They have no locking mechanism.