Operation

R&S

®

HL300

16

Manual 4097.3328.02 ─ 01

The toggle switch remains in its position ; to deactivate the LNA move the switch back
into position “OFF”.

3.4 Notes on Practical Use

3.4.1 How to hold the R&S

 

HL300

To ensure optimum DF results, you have to carry the R&S

 

HL300 with your arm stretched

out for locating the maximum.

Fig. 3-5: Manual direction finding by locating the maximum.

The center of rotation should be located in the antenna rather than your body. Moving
the antenna to and fro is unfavorable since the search for maximum reception is impaired
by site-dependent level differences occurring in disturbed electromagnetic fields.

 

 

Notes on Practical Use

Summary of Contents for 4097.3005.02

Page 1: ...R S HL300 Handheld Log Periodic Antenna Manual Manual X QL2 4097 3328 02 01 Radiomonitoring Radiolocation...

Page 2: ...89 41 29 12 164 E mail info rohde schwarz com Internet http www rohde schwarz com Printed in Germany Subject to change Data without tolerance limits is not binding R S is a registered trademark of Roh...

Page 3: ...9 2 3 Attaching the Belt to the Antenna 11 3 Operation 14 3 1 Operating Elements on the Handle 14 3 2 RF and Control Cable 14 3 3 Activating or Deactivating the LNA in the R S FSH4 8 15 3 4 Notes on P...

Page 4: ...Contents R S HL300 4 Manual 4097 3328 02 01...

Page 5: ...MHz to 8 GHz is covered by a log periodic dipole array antenna structure with a distinct directional pattern The antenna does not have to be tuned within its frequency range A built in GPS receiver wi...

Page 6: ...ncy independent directional pattern GPS receiver and electronic compass Toggle switch for activating and deactivating the LNA within the R S FSH4 8 indi cation by adjacent LED RF and control cable len...

Page 7: ...length max width max depth approx 580 mm approx 310 mm approx 90 mm Weight approx 1 kg excluding transport bag Temperature ranges Operating temperature range Nominal temperature range Storage temperat...

Page 8: ...rint version 1 5 Recommended Extras The following extras are recommended Designation Order number R S FSH4 8 Handheld Spectrum Analyzer 1309 6000 xx Commercial tripod available in specialist shops 1 6...

Page 9: ...the tripod via the tripod s fastening screw 2 2 Assembling the Belt Upon delivery the belt is disassembled It consists of the following components 1 belt 2 fastening straps Fig 2 1 Belt 1 and fasteni...

Page 10: ...ion for Use R S HL300 10 Manual 4097 3328 02 01 Fig 2 2 Attaching the fastening strap step 1 1 belt 2 fastening strap Fig 2 3 Attaching the fastening strap step 2 1 belt 2 fastening strap Assembling t...

Page 11: ...the fastening strap step 3 1 belt 2 fastening strap 2 3 Attaching the Belt to the Antenna Attach the two fastening straps 1 Place the handle onto the neoprene sides of the fastening straps see figure...

Page 12: ...h them firmly to the velcro strips see figure 2 6 Fig 2 6 Attaching the belt step 2 1 rear fastening strap 2 forward fastening strap 2 3 1 Correct Position of the Carrying Belt When you use the belt m...

Page 13: ...Preparation for Use R S HL300 13 Manual 4097 3328 02 01 Fig 2 7 Correct position of the carrying belt longer side facing inwards neoprene side resting on the shoulder Attaching the Belt to the Antenna...

Page 14: ...c compass module 2 status LED 3 toggle switch 3 2 RF and Control Cable The RF and control cable protruding from the R S HL300 connects the antenna to the R S FSH4 8 spectrum analyzer It is approximate...

Page 15: ...and display unit into position OFF downwards on the handle see figure 3 4 Active mode Move the toggle switch on the handle of the supply and display unit into position ON upper position see figure 3...

Page 16: ...results you have to carry the R S HL300 with your arm stretched out for locating the maximum Fig 3 5 Manual direction finding by locating the maximum The center of rotation should be located in the an...

Page 17: ...nged Reflections and interference occur if electromagnetic waves come into contact with objects that have a high dielectric constant or are conductive In a disturbed environment direction finding shou...

Page 18: ...not light up when you activate the LNA there is a potential problem with the connection to the R S FSH4 8 spectrum analyzer In order to verify the connection check the control cable connector check t...

Page 19: ...Maintenance and Repair R S HL300 19 Manual 4097 3328 02 01 Fig 4 1 R S HL300 transport bag 1 velcro fastener Storage and Transport...

Page 20: ...Patterns R S HL300 20 Manual 4097 3328 02 01 5 Diagrams and Patterns 5 1 VSWR Fig 5 1 R S HL300 typical VSWR 5 2 Antenna Factor and Practical Gain Fig 5 2 R S HL300 typical antenna factor and practic...

Page 21: ...Diagrams and Patterns R S HL300 21 Manual 4097 3328 02 01 5 3 Radiation Patterns Fig 5 3 R S HL300 typical E field pattern Fig 5 4 R S HL300 typical H field pattern Radiation Patterns...

Page 22: ...List of Appendices R S HL300 22 Manual 4097 3328 02 01 6 List of Appendices Appendices Drawing 4097 3005 01 D1...

Reviews: