Operating the R&S
QAR
R&S
®
QAR
63
User Manual 1178.7200.02 ─ 09
2. Normalize the measurement, as described in
Chapter 5.3.3.1, "Normalization"
3. Place the bumper to measure in the right position, as described in
4. Measure the attenuation, as described in
Chapter 5.3.3.2, "Attenuation Measure-
5. Save the measurement results, if needed.
"Managing measurement results"
5.3.1
Test Setup
► Place the bumper between the R&S
QAR and the reference reflector, at a mini-
mum distance of 30 mm from the reflector pins.
5.3.2
Graphical User Interface
The graphical user interface (GUI) contains several elements.
2
1
3
4
5
8
9
7
10
6
Figure 5-17: Software user interface
1 = Menu bar
2 = Bumper type selection
3 = System messages
4 = Normalize button
5 = Result display
6 = Result display hide / unhide
Bumper Measurements