Remote command:
Basic Pulse Generator Settings
If option R&S
ZNA-K7 is not available, the port-related pulse generators can only oper-
ate at a fixed duty cycle.
Fixed Duty Cycle/Duty Cycle
If "Fixed Duty Cycle" is enabled, the analyzer automatically adjusts the pulse width of
the the port-related pulse generators to keep the "Duty Cycle" at the specified percent-
age. The same pulse width and the minimum possible pulse delay are used for all
sources.
These settings are only enabled, if
Remote command:
[SENSe<Ch>:]PULSe:FXDCycle[:STATe]
[SENSe<Ch>:]PULSe:DUTYcycle
Advanced Pulse Generator Settings
Advanced settings for the port-related pulse generators are only available, if the
R&S
ZNA is equipped with option R&S
ZNA-K7.
Mode Softtool