Remote Commands
R&S
®
Spectrum Rider FPH
324
User Manual 1321.1011.02 ─ 11
SOURce:TG:ATTenuation
<OutputLevel>
This command defines the relative output level of the tracking generator.
Parameters:
<OutputLevel>
Range:
0 to 40
*RST:
0
Default unit: DB
Example:
SOUR:TG:ATT 40
Sets the attenuation to 40 dB and therefore an output level of –
40 dBm
SOURce:TG:AUTO
<TgSourceMode>
This command selects the generator mode (TG or CW).
Parameters:
<TgSourceMode>
ON | OFF
*RST:
OFF
Example:
SOUR:TG:AUTO ON
Selects tracking generator.
Example:
SOUR:TG:AUTO OFF
Selects continuous wave signal generator.
SOURce:TG:FREQuency
<TgSourceFrequency>
This command defines the frequency of the generated signal.
Available when zero span has been turned on, for example with
Parameters:
TgSrcFreq
Frequency of the CW signal.
*RST:
OFF
Default unit: Hz
Example:
SOUR:TG:AUTO ON
SOUR:TG:FREQ 500MHZ
SOUR:TG:POW -10
Generates a CW signal with 500 MHz and a power of -10 dBm in zero span.
SOURce:TG:FREQuency:AUTO
<TgAutoFrequency>
This command coupled the frequency of the CW signal as the center frequency of the
current measurement.
Parameters:
<TgAutoFrequency> *RST:
OFF
Default unit: Hz