Remote Control - Commands
R&S NRP-Z28/-Z98
1170.8966.12
6.20
E-4
Fig. 6-5
Effect of
SENSe:TIMing:EXCLude:STARt
and
:STOP
in the
Timeslot Average
mode
SENSe:TRACe:AVERage:COUNt[?] 1 to 8192
SENSe:TRACe:AVERage:COUNt
is used to set the averaging factor for the
Trace
mode. To put the
setting into effect, you must also activate averaging for the
Trace
mode and deactivate the
Realtime
mode (settings
SENSe:TRACe:AVERage:STATe ON
and
SENSe:TRACe:REALtime OFF
). When trace
averaging is activated, the measurement is always performed with chopper stabilization, i.e. the number
of recorded sampling sequences is twice as large as the averaging factor (alternating measurements
with reversed and non-reversed polarity). The result is that two sampling sequences are recorded if the
averaging factor is 1, eight if the averaging factor is 4, and so forth. If the averaging factor transmitted to
the sensor is not a power of two, the parameter is rounded up or off to the next power-of-two number.
The query yields the averaging factor used in the sensor for the
Trace
mode.
Default setting:
4
SENSe:TRACe:AVERage:STATe[?] OFF | ON
SENSe:TRACe:AVERage:STATe
switches the averaging filter on or off for the
Trace
mode.
The query yields
•
1
for
OFF,
•
2
for
ON
.
Default setting:
ON