background image

 

10

OWNER AND WARRANTY REGISTRATION FORM 

Included with this manual is an Owner and Warranty Registration Form. Please 
take a minute to fill out this card and return it to Rogue Audio.  This card must be 
returned within 15 days of purchase to validate the warranty. 

 

LIMITED WARRANTY 

Warranty Period 

This product has been manufactured under the highest standards of quality and workmanship. Rogue Audio 

Inc. (hereinafter “Rogue Audio”) warrants this product against defects in material or workmanship as 
follows: 

With the exception of vacuum tubes, Rogue Audio warrants to the original purchaser of this product all 

parts of this product against defects in material and workmanship for a period of three years from the date of 
retail purchase. Rogue Audio warrants the vacuum tubes for a period of six months from the date of retail 
purchase. Any defective parts will be replaced free of charge, excluding shipping and handling.  

Proof of purchase in the form of a bill of sale or recited  invoice which indicates that the product is within 

the warranty period must be presented to obtain warranty service. Rogue Audio suggests that the purchaser 
retain the dealer’s bill of sale as evidence of the date of retail purchase.  

 

What’s Not Covered 

This warranty does not cover cosmetic damage or any damage that results from product misuse, product 

abuse, installation error, connection to an improper voltage supply, accident, improper maintenance, 
alterations, modifications not authorized in writing by Rogue Audio, lightening, power surges, or acts of God. 
Use of any other than Rogue Audio factory parts may void this warranty

.  

This warranty does not cover the cost of parts and labor which would be otherwise provided without charge 

under this warranty, obtained from any source other than Rogue Audio. 

This warranty applies only to consumer use of this product and does not cover any product that is used in 

any trade or business, or in an industrial or commercial application

This warranty applies only to the original purchaser of this product when purchased from an Authorized 

Rogue Audio dealer.  This warranty is not transferable. 

This warranty is valid only in the United States.  

YOUR RIGHTS 

ROGUE AUDIO LIMITS ITS OBLIGATIONS UNDER ANY IMPLIED WARRANTIES UNDER STATE 
LAWS TO A PERIOD NOT TO EXCEED THE WARRANTY PERIOD. SOME STATES DO NOT 
ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, AND SOME STATES 
DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL 
DAMAGES, SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY

 TO YOU. THIS 

WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY HAVE OTHER 
RIGHTS WHICH MAY VARY FROM STATE TO STATE.  

 

To Obtain Service 

To obtain service, you must contact Rogue Audio and obtain a return authorization number. The product 
must be delivered to Rogue Audio in its original packaging prepaid at the following address

 

Rogue Audio Inc. 

3 Marian Lane 

Brodheadsville, PA 18322

 

 

Summary of Contents for TEMPEST II

Page 1: ...TEMPEST II Vacuum Tube Integrated Amplifier Owner s Manual Rogue Audio Inc 3 Marian Lane Brodheadsville PA 18322 Issue date 02 9 05...

Page 2: ...roduction 2 2 Unpacking the Tempest II amplifier 2 3 Installing the Tempest II into your system 3 4 Operation of the Tempest II 5 5 Setting the tube bias 7 6 Troubleshooting 8 7 Fuse values 9 8 Specif...

Page 3: ...gged The Tempest II has been painstakingly inspected for cosmetic flaws during and after assembly In order not to damage the cosmetic appearance of your amplifier it is important that you follow the u...

Page 4: ...t be placed in a fully enclosed shelf and should have a minimum of 8 inches of free space above it and 6 inches of free space on either side Connecting the Tempest II to the Loudspeakers The Tempest I...

Page 5: ...erate the amplifier unless it is connected to a loudspeaker Connecting the Tempest II to the source components The input connections to the Tempest II are made via RCA jacks on the rear of the amplifi...

Page 6: ...e Tempest II is equipped with volume balance source power mute and an optional remote volume Volume adjust gain from 0 to 23Volts out Balance left and right channel attenuation Source selects source m...

Page 7: ...r small shunts on the control circuit board as shown in figure 1 3 Using a needle nose pliers carefully remove the four shunts from the locations marked int pre and move them to the adjacent locations...

Page 8: ...simple and effective On some amplifiers biasing is done for two or more tubes simultaneously With this method the total current flowing through the group of tubes may be correct but the current flow...

Page 9: ...ube bias should be checked every few months if possible Note that the bias will change slightly on a day to day basis as the wall voltage fluctuates Constant biasing will wear out the bias potentiomet...

Page 10: ...Fuses 4 1 4 Amp slow blow SPECIFICATIONS output power 90 WPC frequency response 5Hz 50 kHz 1dB THD 0 1 typ 1 at rated power input sensitivity 1 0 V RMS dimensions 14 W x 19 D x 7 H weight 60 pounds 25...

Page 11: ...connection to an improper voltage supply accident improper maintenance alterations modifications not authorized in writing by Rogue Audio lightening power surges or acts of God Use of any other than R...

Reviews: