Design and application  

RWH-1 is a wireless hub dedicated to RACS 5 

AIR system. The hub enables connection of 
wireless devices to RS485 bus and their 

control by MC16 access controller or other 
device which controls the bus (e.g. bus 
expander). The hub and connected wireless 

devices form radio network which operates in 
selected channel with specified network 

identifier. The hub can operate with up to 8 
wireless devices of all available types such as 

RWL series lock (e.g. RWL-1, RWL-2) and 
RWX series expanders (e.g. RWX-1, RWX-2). 
Devices connected to the MC16 controller via 

RWH-1 are operated in the same way as wired 
devices connected to the MC16 and their 

functions can be freely configured with VISO 
management software. Multiple hubs can be 
connected to a single access controller forming 

multiple RACS 5 AIR radio networks. The 
maximal number of hubs connected to 

particular controller is limited by the number 
of unoccupied addresses on its RS485 bus 

while the maximal number of all devices 
operated by the MC16 results from its 
firmware and license. The same MC16 

controller can operate with wireless and wired 
devices. 

Creation of wireless networks 

Prior to connection of wireless devices to 

access control system it is necessary to make 
low level configuration of these devices and 

then connect them within radio network. Both 
can be done with RogerVDM software. 

 
 
 
 
 

Fig. 1 Connection of peripheral devices to MC16 
access controller 

Summary of Contents for RWH-1

Page 1: ...Roger Access Control System RWH 1 v1 x RACS AIR Wireless Hub Operating Manual Firmware version 1 0 Document version Rev B ...

Page 2: ...n the same way as wired devices connected to the MC16 and their functions can be freely configured with VISO management software Multiple hubs can be connected to a single access controller forming multiple RACS 5 AIR radio networks The maximal number of hubs connected to particular controller is limited by the number of unoccupied addresses on its RS485 bus while the maximal number of all devices...

Page 3: ...ed disturbances will affect the system and hinder its operation Wi Fi channels Channel Frequency range GHz Channel Frequency range GHz 1 2 401 2 423 2 412 8 2 436 2 458 2 447 2 2 406 2 428 2 417 9 2 441 2 463 2 452 3 2 411 2 433 2 422 10 2 446 2 468 2 457 4 2 416 2 438 2 427 11 2 451 2 473 2 462 5 2 421 2 443 2 432 12 2 456 2 478 2 467 6 2 426 2 448 2 437 13 2 461 2 483 2 472 7 2 431 2 453 2 442 1...

Page 4: ...nfiguration parameters The table below includes RWH 1 configuration parameters which can be modified using RogerVDM software within low level configuration of device Parameter Function RS485 address The parameter defines device address on RS485 bus Range 100 115 RS485 encryption When the option is enabled then the communication between device and access controller is encrypted RS485 encryption key...

Page 5: ...e hub Wireless network creation Devices within the same radio network must work in the same channel and be assigned with the same identifier PAN ID The selection of channel and PAN ID can be done automatically when the network is created using RogeVDM software Nevertheless it is recommended to select radio channel and PAN ID manually during low level configuration of the hub In such case all devic...

Page 6: ...k configuration or perform a factory reset of the wireless device in accordance with its instruction manual RACS AIR tab buttons Name Function New configuration Deletes current configuration and creates new one Save configuration Uploads current configuration to hub Add devices Opens network scanning window Remove device Deletes chosen device LED indicators RWH 1 hub is equipped with 4 LED indicat...

Page 7: ...from manufacture warranty The enclosure base must be installed according to orientation shown in fig 3 so the tamper lever could press the contact It is recommended to mount the hub on flush mounting box but it can also mounted directly on the wall with included screws Connection cable should be led through the hole in the base and connected to the screw terminals at hub front panel Connection dia...

Page 8: ...RWH 1 Operating manual doc 2018 11 30 Page8 of 11 Fig 4 Connection between hub and controller ...

Page 9: ... guidelines All electric cables must be connected to devices with disconnected power supply Installation near metal elements decreases wireless range If hub and access controller are not supplied from the same PSU then GND terminals of both devices should be connected Clean front panel regularly with wet cloth and mild detergent Do not clean by means of abrasive materials and such strong cleaners ...

Page 10: ... 4GHz wireless communication range 10m in free space Environmental class according to EN 50131 1 Class II indoor general conditions temperature 10 C to 40 C relative humidity 10 to 95 no condensation IP code IP40 Dimensions H x W x D 85 x 85 x 22 mm Weight 100g Certificates CE mark Ordering information Product Description RWH 1 RS485 interface to RACS 5 AIR devices RWL 1 Wireless door lock with es...

Page 11: ...f electric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and recycling of this type of waste contributes to the protection of the natural resources and is safe to health and the environment Weight of the equipment is specified in the document Contact Roger sp z o o sp k 82 400 Sztum Gościsze...

Reviews: