background image

PRT12MF PRT62MF PRT64MF PRT66MF Installation Manual.doc 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2019-07-02 

 

2/2 

 

F

IRMWARE UPDATE

 

The  update  requires  connection  of  reader  to  computer  with  RUD-1  interface     
(fig.  1)  and  starting  RogerISP  software.  The  latest  firmware  file  is  available  at 

www.roger.pl

Firmware update procedure: 

1.  Connect  the  reader  to  RUD-1  interface  (fig.  1)  and  connect  the  RUD-1  to 

computer’s USB port. 

2.  Place jumper on FDM contacts (fig. 2). 
3.  Restart the reader (switch power supply off and on or short RST contacts for 

a moment). 

4.  Start RogerISP program. 
5.  Select serial port with RUD-1 interface and 

Device Programmer

 option. 

6.  Specify path to firmware file (*.hex). 
7.  Click 

Update 

to start firmware upload with progress bar in the bottom. 

8.  When the  update is finished,  remove jumper from FDM contacts  and restart 

the reader. 

Note:  After  firmware  update  it  may  be  necessary  to  start  Memory  reset 
procedure. 

A

PPENDIX

 

 

Fig. 2 Service contacts 

Table 1. Terminals and wires 

Screw 
terminal 

Wire colour 

Description 

12V 

Red 

Supply plus 

GND 

Black 

Ground 

IN1 

Yellow 

IN1 input line 

IN2 

Blue 

IN2 input line 

RTS 

Violet 

RS232 interface RTS line 

CLK 

Green 

CLK line 

DTA 

Brown 

DTA line 

TMP 

White 

Tamper switch 

TMP 

Grey 

Tamper switch 

NC 

Grey-pink 

REL1 relay output (NC) 

COM 

Red-blue 

REL1 relay common terminal 

NO 

Pink 

REL1 relay output (NO) 

 

Table 2. Specification 

Supply voltage 

Nominal 12VDC, min./max. range 10-15VDC 

Current 

consumption 

(average) 

PRT12MF/PRT64MF:  

 

 

 

~85 mA 

PRT12MF-BK/PRT62MF/PRT66MF: ~65 mA 

Inputs 

Two  (IN1..IN2)  NO  inputs,  approx.  3.5  triggering 
level  

Relay output 

Relay  output  (REL1)  with  single  NO/NC  contact, 
30V/1.5A  DC/AC  max.  load,  available  only  in 
PRT64MF and PRT66MF 

Tamper protection 

Isolated  50mA/24V  contacts,  shorted  when 
enclosure is closed 

Proximity cards 

13.56MHz according to ISO14443A and MIFARE 

Reading range 

Up to 6 cm. 

Note:  Reading  distance  is  defined  for  good  quality 
proximity  cards  placed  in  optimal  position  against  the 
reader. For all readers the optimal position for card reading 
is  in  the  front  of  the  device  (card  surface  parallel  to  the 
front).

 

Distances 

150m  maximal  cable  length  for  RACS  CLK/DTA 
bus between controller and reader 

IP Code 

IP65 

Environmental class 
(according to EN 50133-1) 

Class IV, outdoor general conditions, temperature: 
-

25°C  to  +60°C,  relative  humidity:  10  to  95%  (no 

condensation) 

Dimensions H x W x D and 
weight 

PRT12MF: 152,5 x 46 x 23(35) mm; 150g 
PRT62MF: 100 x 45 x 25 mm; 100g 
PRT64MF: 115 x 80 x 35 mm; 120g 
PRT66MF: 85 x 85 x 27 mm; 120g 

Certificates 

CE 

 

 

Fig. 3 Connection of door lock and exit button to PRT64MF or PRT66MF reader 
– Simple standalone mode 

Note:  PRT12MF  and  PRT62MF  readers  are  not  equipped  with  relay.  In  their 
case  a  door  lock  can  be  controlled  by  external  relay  connected  to  configured 
CLK or DTA transistor output. 

 

Fig. 4 Connection of PRT readers in RACS 4 system 

– terminal (online) mode 

 

Fig. 5 Connection of reader to controller via Wiegand interface 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

This  symbol  placed  on  a  product  or  packaging  indicates  that  the 
product  should  not  be  disposed  of  with  other  wastes  as  this  may 
have a negative impact on the environment and health. The user is 
obliged  to  deliver  equipment  to  the  designated  collection  points  of 
electric and electronic waste. For detailed information on recycling, 
contact  your  local  authorities,  waste  disposal  company  or  point  of 
purchase.  Separate  collection  and  recycling  of  this  type  of  waste 
contributes to the protection of the natural resources and is safe to 
health and the environment. Weight of the equipment is specified in 
the document. 

 

Contact: 

Roger Sp. z o. o. sp. k. 

82-400 Sztum 

Gościszewo 59 

Tel.: +48 55 272 0132 
Fax: +48 55 272 0133 

Tech. support: +48 55 267 0126 

E-mail: 

[email protected]

 

Web

www.roger.pl

 