PR611 and PR621 Installation guide Rev.B EN
2009-11-06
Page
6
of
13
Firmware Upgrade
During manufacturing process controller is programmed with a latest available version of firmware.
The firmware can be later upgraded to newer versions. Detailed description of the firmware upgrade
procedure can be found in the
Firmware upgrade.pdf
manual available at www.roger.pl. Loading an
upgraded firmware to the controller is done using RS485 communication bus and does not require
dismounting the device from the place of installation. RogerISP is the software used for upgrading
firmware (it can be downloaded at
www.roger.pl
). After the firmware is upgraded, always perform
the
Memory Reset
procedure and assign a proper ID address to the controller. If the controller
being upgraded worked in the RACS system before, you need to assign to it appropriate ID address
after the upgrade (the same which it was assigned before the upgrade). Then, you need to go to the
PR Master managing software, and run the command:
/Subsystems/Controllers/Commands/Restart, verify type and version
– the operation will
update data related to the controller’s firmware version in the RACS system database.
Note: Together with the controller’s firmware upgrade, you need also to update the managing PR
Master software.
Summary of Contents for PR611
Page 1: ...Installation Guide for PR611 and PR621 v1 0 Access Controllers Rev B ...
Page 11: ...PR611 and PR621 Installation guide Rev B EN 2009 11 06 Page 11 of 13 ...
Page 12: ...PR611 and PR621 Installation guide Rev B EN 2009 11 06 Page 12 of 13 ...
Page 13: ...PR611 and PR621 Installation guide Rev B EN 2009 11 06 Page 13 of 13 ...