In order to configure F11 reader for work with access controller the first step is to connect the reader to PC by means of TCP/IP. Then proceed 
as follows:

1.

 Install and start Enrollment&Management Software or Access Control Software in version 2.4.4.1041.

2.

 Click 

Device Manager

.

3.

 Click 

Add

 in order to add new reader to the list.

4.

 Point 

Ethernet

 from the list.

5.

 Enter IP address 

192.168.1.201

.

6.

 Optionally enter custom reader name in 

Name

 field.

7.

 Click 

Test

 connection in order to verify the connection and click 

OK

.

8.

 Choose the reader from the list on the left and click 

Communication

 tab.

9.

 In the lower part of the window click 

Read Options

 in order to fill values in the section 

Communication

 

options

.

10.

 Enter target communication parameters such as IP address and/or port and then click 

Set options

.

11.

 After settings are uploaded it is necessary to restart the reader (for example by switching power off). 

12.

 Connect F11 reader with controller according to diagram.

13.

 Install and/or start PR Master software in version 4.4.12 or newer.

14.

 Select 

Wiegand communication

 mode [17] in the properties of controller by means of PR Master software.

15.

 Add the reader to RACS 4 system by means of the option 

Fingerprint

 

readers

 in the main window of PR Master software.

16.

 Add users by means of the option 

Users

 in the main window of PR Master software.

in case of any problems in communication with the reader, download library pack F11dll.zip from www.roger.pl and proceed as 
follows:

Windows XP:

1.

 Unpack „F11dll.zip”.

2.

 Copy all files from folder F11dll and replace files in directory „C:\WINDOWS”.

3.

 Copy all files from folder F11dll and replace files in directory „C:\WINDOWS\system32”.

4.

 Copy all files from folder F11dll and replace files in directory „C:\Program Files\Roger\Access Control System 4.4\Dlls”.

Windows 7 x64/x32:

1. 

Unpack „F11dll.zip”.

2.

 Copy all files from folder F11dll and replace files in directory „C:\WINDOWS”.

3.

 Copy all files from folder F11dll and replace files in directory „C:\WINDOWS\system32”.

4.

 Copy all files from folder F11dll and replace files in directory „C:\Program Files(x86)\Roger\Access Control System 4.4\Dlls”.

In case of problem with coping msvcr71.dll file to „system32” directory you can skip this file.

Quick s

tar

t guide - An e

xample of ac

ces

s c

on

tr

ol s

ys

tem b

as

ed on F1

1 biome

tric r

eader - v

ersion 1.

0EN R

ev

.A © 2

012, R

oger sp. j. r

es

erv

es the righ

t t

o modify the c

on

ten

t and specification of pr

es

en

ted pr

oducts without notic

e. 

This documen

ts does not define f

ull c

onfigur

ation of de

vic

es

. Des

crip

tion of adv

anc

ed f

unctions is giv

en in dedicat

ed manuals

.

Reviews: