PR302 v2.0 

Installer Manual 

Rev. B 

Summary of Contents for PR302

Page 1: ...PR302 v2 0 Installer Manual Rev B ...

Page 2: ...l address ID number 00 99 The controller s address can be set manually using Memory Reset procedure or from PC computer In order to set change controller s address from PC connect it to any free COM port and then using PR Master program enrol it to database Once the unit is found by PR Master use relevant command to change its address and then disconnect it from PC and connect to designated access...

Page 3: ...ts short to supply minus GND Each output can switch max 1A DC while voltage connected to it must not exceed 15V DC The IO1 and IO2 have internal over current protection which switches them off for currents above 1A Communication bus The communications bus consist of three lines A B and cable s shield SHLD Electrically it represents RS485 standard however neither the daisy chain structure nor termi...

Page 4: ...ller and any other device connected to CLK DTA line is limited to 150m nevertheless when using RACS interface communication will run satisfactory for up to 500m distances however it is not guaranteed in every case For best card reading results controller should be installed on non metal surface When installed on metal structure the reading range can be reduced up to 50 This effect can be reduced b...

Page 5: ...Read any proximity card this will be a new MASTER card or press to skip this step Enter two digits range 00 00 which will program new ID number address for the unit After this step Memory Rest will be completed and controller returns to normal operations Memory Reset by means of CLK and DTA wires Remove all connections from CLK and DTA lines Short CLK and DTA lines Restart controller power off on ...

Page 6: ...of the controller from live installation The detailed description of firmware upgrade procedure can be found in Firmware upgrade pdf on www roger pl The new firmware is programmed into the controller by means of communication bus and doesn t require de installation of the unit from its original location For firmware upgrade the RogerISP v3 program is required Once the controller is upgraded it sho...

Page 7: ...ne DATA TAMPER Tamper switch line A 24V 50mA rated TAMPER Tamper switch line B 24V 50mA rated IO2 IO2 transistor output 15V DC 1 0A IO1 IO1 transistor output 15V DC 1 0A REL1 NC REL1 output normally closed contact 24V 1 5A rated REL1 COM REL1 output common contact 24V 1 5A rated REL1 NO REL1 output normally open contact 24V 1 5A rated Technical specification Supply voltage 10 15 VDC Current consum...

Page 8: ...2 PCB RM 2 PCB module without enclosure XM 2 Input output addressable extension module with plastic enclosure digital communication according to RACS Clock and Data protocol two NO NC inputs and two relay outputs each relay offers one NO NC contact 1 5A 24V rated relay contacts protected by over voltage components two LEDs to indicate triggering of relevant relay XM 2 PCB RM 2 PCB module without e...

Page 9: ...PR302 v1 0 Installer Manual EN Rev B doc 8 19 2008 9 ...

Page 10: ...PR302 v1 0 Installer Manual EN Rev B doc 8 19 2008 10 ...