Roger MCX2D Installation Manual Download Page 2

MCX2D and MCX4D Installation Manual 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2020-11-12 

 

2/2 

 

A

PPENDIX

 

 

Fig. 3 MCX2D and MCX4D expanders 

Table 3. Screw terminals 

Name 

Description 

BAT+, BAT- 

Backup battery 

VIN+, VIN- 

13.8VDC input power supply 

AUX+, AUX- 

13.8VDC/0.2A output power supply (for general purpose) 

VOUT+, VOUT- 

13.8VDC/0.2A output power supply (to controller) 

A, B 

RS485 bus (to controller) 

Ax*, Bx 

RS485 bus (to readers) 

TMLx+, TMLx- 

13.8VDC/0.2A output power supply (to readers) 

VDRx+, VDRx- 

13.8VDC/1.0A output power supply (to door lock) 

LCKx 

15VDC/1A transistor output line (door lock) 

BELLx 

15VDC/1A transistor output line (alarm signalling device) 

DCx 

Input line (door contact) 

DRx 

Input line (exit button) 

* x symbol corresponds to the number of particular door controlled via expander 
 

Table 4. LED indicators 

Indicator 

Colour 

Integral functions 

ACL 

Red 

In normal mode the LED indicates backup power 
supply from battery instead of PSU. 

RUN  

Red 

Single pulse every 4 sec. : normal mode 
Quick pulsing: service mode 
Slow pulsing (0.5s/0.5s): No communication with 
controller 
Very slow pulsing (1s/1s): Configuration memory 
error 
 
In  case  of  Memory  reset  this  LED  is  used  for 
manual addressing. 

TXD 

Red 

LED indicates data transmission to controller  

RXD 

Green 

LED indicates data receiving from controller 

VDR, TML, 
VOUT, AUX 

Green 

LED indicates voltage at particular output. 

LCK 

Red 

LED  is  on  when  corresponding  LCK  output  is 
switched on. 

 

Table 5. Specification 

Supply voltage 

13.8VDC; +/- 100mV (backup battery connected) 
11-15 VDC (no backup battery) 

Current 

consumption 

(average) 

MCX2D/MCX4D expander: 50mA 
MCX2D  expander  with  maximal  load  at  power 
outputs  and  maximal  battery  charging  current: 
3.5A 
MCX4D  expander  with  maximal  load  at  power 
outputs  and  maximal  battery  charging  current: 
6.0A 

Battery charging current 

Configurable: 0.3A/0.6A/0.9A 

Inputs 

MCX2D: Four (DCx, DRx) parametric inputs 
MCX4D: Eight (DCx, DRx) parametric inputs 

Transistor outputs 

MCX2D:  Four  (LCKx,  BELLx)  outputs,  each  with  
15V/1A DC max load 
MCX4D:  Eight  (LCKx,  BELLx)  outputs,  each  with  
15V/1A DC max load 

Power supply outputs 

MCX2D: 
Two 13.8VDC/0.2A outputs (VOUT, AUX) 
Two 13.8VDC/0.2A outputs (TML) 
Two 13.8VDC/1.0A outputs (VDR) 
 
MCX4D: 
Two 13.8VDC/0.2A outputs (VOUT, AUX) 
Four 13.8VDC/0.2A outputs (TML) 
Four 13.8VDC/1.0A outputs (VDR) 

Distances 

Up to 1200 m between  MC16 controller and  MCX 
expander (RS485). 
Up  to  1200  m  between  MCX  expander  and  MCT 
terminals (RS485) 
The  total  distance  between  controller  and  any 
terminal cannot exceed 1200m. 

IP Code 

IP20 

Environmental 

class 

(according to EN 50133-1) 

Class  I,  indoor  general  conditions,  temperature: 
+5°C  to  +40°C,  relative  humidity:  10  to  95%  (no 

condensation) 

Dimensions W x S x G  

MCX2D:  

80 x 80 x 20 mm 

MCX4D: 

80 x 115 x 20 mm 

Weight 

MCX2D:  

65g 

MCX4D:  

85g 

Certificates 

CE 

 
 

 

Fig. 4 Connection of readers and expanders to MC16 access controller 

Notes: 

  In case of MCX4D the connection diagram is similar to the one shown in fig. 4 

with the exception of MC16-PAC-4 controller, PS4D power supply unit and up 
to four doors control. 

  All  MCT  readers  connected  to  the  MC16  controller  via  MCX2D/MCX4D 

expander  must  have  unique  addresses  on  RS485  bus  in  range  of  101-115 
(assuming that expander is operated with default ID=100 address). 

  In  case  of  read-in  door,  single  reader  is  connected  to  the  controller  within 

particular door. 

  Diagrams  include  doors  with  electric  strikes.  In  case  of  electromagnetic  lock, 

the  polarity  of  LCKx  output  must  be  changed  within  low  level  configuration  of 
MCX2D/MCX4D expander by means of RogerVDM software. 

  Diagrams  include  exit  buttons.  In  case  of  read-in/out  doors  they  can  be  used 

for emergency door opening. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

This  symbol  placed  on  a  product  or  packaging  indicates  that  the 
product  should  not  be  disposed  of  with  other  wastes  as  this  may 
have a negative impact on the environment and health. The user is 
obliged  to  deliver  equipment  to  the  designated  collection  points  of 
electric and electronic waste. For detailed information on recycling, 
contact  your  local  authorities,  waste  disposal  company  or  point  of 
purchase.  Separate  collection  and  recycling  of  this  type  of  waste 
contributes to the protection of the natural resources and is safe to 
health and the environment. Weight of the equipment is specified in 
the document. 

 