background image

MCT82-FK Installation Manual   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2020-07-24 

 

2/2 

 

 

Fig. 5 Connection of peripheral devices to MC16 access controller 

Table 2. Specification 

Supply voltage 

Nominal 12VDC, min./max. range 10-15VDC 

Current 

consumption 

(average) 

~60 mA 

Tamper protection 

Enclosure opening reported to access controller 

Distance 

1200m  maximal  cable  length  for  RS485  bus 
between controller and panel 

IP Code 

IP41 

Environmental 

class 

(according to EN 50133-1) 

Class  II,  indoor  general  conditions,  temperature:  -
10°C  to  +50°C,  relative  humidity:  10  to  95%  (no 
condensation) 

Dimensions H x W x D 

MCT82-FK: 

85 x 85 x 22 mm 

MCT82-FK-HR-F:  

105 x 105 x 31 mm 

Weight 

~100g 

Certificates 

CE 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

This  symbol  placed  on  a  product  or  packaging  indicates  that  the 
product  should  not  be  disposed  of  with  other  wastes  as  this  may 
have a negative impact on the environment and health. The user is 
obliged  to  deliver  equipment  to  the  designated  collection  points  of 
electric and electronic waste. For detailed information on recycling, 
contact  your  local  authorities,  waste  disposal  company  or  point  of 
purchase.  Separate  collection  and  recycling  of  this  type  of  waste 
contributes to the protection of the natural resources and is safe to 
health and the environment. Weight of the equipment is specified in 
the document. 

 

Contact: 

Roger Sp. z o. o. sp. k. 

82-400 Sztum 

Gościszewo 59 

Tel.: +48 55 272 0132 
Fax: +48 55 272 0133 

Tech. support: +48 55 267 0126 

E-mail: 

[email protected]

 

Web

www.roger.pl

 

Reviews: