MCT82-FK Installation Manual   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2020-07-24 

 

1/2 

 

Roger Access Control System 

MCT82-FK / MCT82-FK-HR-F Installation Manual 

Firmware version: 1.1.25.244 and newer 

Document version: Rev. A 

 

 

This  document  contains  minimum  information  that  is  necessary  for  initial  setup 
and  installation  of  the  device.  The  detailed  description  of  configuration 
parameters  and  functionalities  is  specified  in  respective  Operating  Manual 
available a

www.roger.pl

I

NTRODUCTION

 

Both  versions  of  the  panel  with  four  touch  function  keys  i.e.  MCT82-FK  (wall 
mounting)  and  MCT82-FK-HR-F  (flush  mounting)  are  designed  to  operate  in 
RACS 5 system as peripheral devices connected to RS485 bus of MC16 access 
controller. Factory new panel is configured with default settings including ID=100 
address.  Before  connecting  to  controller,  the  device  should  be  assigned  with 
unoccupied  address  in  range  of  100-115.  Programming  of  other  parameters 
depends on the individual  requirements and is not  obligatory. Addressing  of the 
panel  can  be  done  from  computer  by  means  of  RogerVDM  program. 
Configuration of the panel with RogerVDM requires RUD-1 interface. 

C

ONFIGURATION WITH 

R

OGER

VDM

 PROGRAM

 

 

Fig. 1 Connection of panel to RUD-1 interface for configuration 

Programming procedure: 

1.  Connect  the  device  to  RUD-1  interface  (fig.  1)  and  connect  the  RUD-1  to 

computer’s USB port. 

2.  Restart the device (switch power supply off and on or short RST contacts for 

a moment) 

3.  Within  2-3  seconds  place  jumper  on  MEM  contacts  (fig.  3)  and  all  LED 

indicators will pulsate quickly. 

4.  Start  RogerVDM  program,  select 

MCT

  device,  firmware  version, 

RS485

 

communication channel and serial port with RUD-1 interface. 

5.  Click 

Connect,

  the  program  will  establish  connection  and  will  automatically 

display 

Configuration

 tab. 

6.  Enter  unoccupied  RS485  address  in  range  of  100-115  and  other  settings 

according to requirements of specific installation. 

7.  Click 

Send to Device

 to update the configuration. 

8.  Optionally  make  a  backup  by  clicking 

Send  to  File… 

and  saving  settings  to 

file on disk. 

9.  Remove  jumper  from  MEM  contacts  and  disconnect  device  from  RUD-1 

interface. 

F

IRMWARE UPDATE

 

The  update  requires  connection  of  device  to  computer  with  RUD-1  interface     
(fig.  2)  and  starting  RogerVDM  software.  The  latest  firmware  file  is  available  at 

www.roger.pl

Firmware update procedure: 

1.  Connect  the  device  to  RUD-1  interface  (fig.  2)  and  connect  the  RUD-1  to 

computer’s USB port. 

2.  Place jumper on FDM contacts (fig. 3). 
3.  Restart the device (switch power supply off and on or short RST contacts for 

a moment). 

4.  Start RogerVDM program and in the top menu select 

Tools

 and then 

Update 

firmware

5.  In  the  opened  window  select  device  type,  serial  port  with  RUD-1  interface 

and path to firmware file (*.hex). 

6.  Click 

Update 

to start firmware upload with progress bar in the bottom. 

7.  When the update is finished, remove FDM jumper and restart the device. 

 

Fig. 2 Connection of panel to RUD-1 interface for firmware update 

A

PPENDIX

 

 

Fig. 3 MCT82-FK enclosure opening and location of service contacts 

 

Fig. 4 Wall mounting for surface and flush versions 

Table 1. Screw terminals 

Screw terminal 

Description 

12V 

Supply plus 

GND 

Ground 

RS485 bus, line A 

RS485 bus, line B 

 