background image

MCT64E MCT66E Operating Manual 

  

09.07.2020 

 

10/15 

 

 

Fig. 8 Typical connection diagram for the terminal and MC16 access controller 

4.

 

C

ONFIGURATION

 

Low level configuration (RogerVDM) 

The purpose of low level configuration is to prepare device for operation in RACS 5 system. 
 
Programming procedure with RogerVDM software: 

1.  Connect the reader to RUD-1 interface (fig. 9) and connect the RUD-

1 to computer’s USB port. 

2.  Start  RogerVDM  program,  select 

MCT

  device,  firmware  version, 

RS485

  communication  channel  and 

serial port with RUD-1 interface. 

3.  Click 

Connect,

 the program will establish connection and will automatically display 

Configuration

 tab. 

4.  Enter unoccupied RS485 address in range of 100-115 and other settings according to requirements of 

specific installation. 

5.  Click 

Send to Device

 to update the configuration of reader. 

6.  Optionally make a backup by clicking 

Send to File… 

and saving settings to file on disk. 

7.  In the top menu select 

Device->Disconnect.

 

8.  Disconnect reader from RUD-1 interface. 

Note: Do not read any cards nor press keypad when reader is configured with RogerVDM. 

Summary of Contents for MCT64E-IO

Page 1: ...Roger Access Control System MCT64E IO and MCT66E IO Operating Manual Product version 1 1 Firmware version 1 0 4 or newer Document version Rev A...

Page 2: ...f 11 15VDC It can be supplied from MCX2D MCX4D expander of MC16 PAC KIT from MC16 access controller e g TML output or from dedicated power supply unit The supply wire diameter must be selected in such...

Page 3: ...The matching resistors terminators connected at the ends of transmitting lines are not required In most cases communication works with any cable type standard telephone cable shielded or unshielded tw...

Page 4: ...uzzer Terminals are equipped with buzzer which is used to signal integral functions and it can be additionally programmed with other available functions within high level configuration VISO Inputs Ter...

Page 5: ...kHz cards EM125kHz proximity cards are widely used in office buildings If it is necessary to ensure higher level of security then MIFARE card readers e g MCT12M are recommended The technical character...

Page 6: ...RS485 bus line B CLK CLK line DTA DTA line TMP Tamper contact TMP Tamper contact IO1 IO1 output line IO2 IO2 output line REL1 NC REL1 relay normally closed contact REL1 COM REL1 relay common contact R...

Page 7: ...MCT64E MCT66E Operating Manual 09 07 2020 7 15 Fig 5 MCT64E IO installation...

Page 8: ...MCT64E MCT66E Operating Manual 09 07 2020 8 15 Fig 6 MCT66E IO installation...

Page 9: ...not clean by means of abrasive materials and strong cleaners like alcohols solvents etc Damages to screen surface are beyond the scope of warranty 3 OPERATION SCENARIOS The terminal when connected to...

Page 10: ...CT device firmware version RS485 communication channel and serial port with RUD 1 interface 3 Click Connect the program will establish connection and will automatically display Configuration tab 4 Ent...

Page 11: ...both readers Selected input must be connected to synchronisation output of another reader When set to 0 then synchronisation is disabled Typical numbering is 1 IN1 2 IN2 and 3 IN3 Range 0 3 Default v...

Page 12: ...led Range 0 100 Default value 100 Input types IN1 IN2 IN3 Parameter defines the type of input line Range 1 NO 2 NC Default value 1 NO Input comments IN1 IN2 IN3 Parameter defines any text or comment w...

Page 13: ...it Zero digit is emulated with 10 readings Example Programming of ID 101 address with card readings 1 Read card 1 time and wait for two beeps 2 Read card 10 times and wait for two beeps 3 Read card 1...

Page 14: ...ronmental class according to EN 50133 1 Class IV outdoor general conditions temperature 25 C to 60 C relative humidity 10 to 95 no condensation Dimensions H x W x D MCT64E IO 115 x 80 x 35 mm MCT66E I...

Page 15: ...electric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and recycling of this type of waste c...