HRT82AC Installation Guide Rev.A
2015-08-13
© 2015 ROGER sp.j. All rights reserved.
8/11
Fig. 6 Device select window in RogerVDM software
Fig. 7 Configuration window in RogerVDM software
Table 6. Configuration parameters
Parameter
Values
Description
General
Device Name
16 ASCII
characters
Device description which can be filled with any comment by
installer
Transmission Format
RACS CLK/DTA
Address
0..15
Device address on RACS CLK/DTA bus. Default address
ID=7 is required for communication with controller.
Communication
timeout
0..255
The device signals communication failure when selected
timeout [0.5s] elapses. When 0 is selected then failure is
not signalled at all.
Optical Signalization
Backlight Dim
On, Off
When activated, panel will temporary switch off keypad
backlight when key is pressed.
Acoustic Signalization
Buzzer loudness
level
0..100%
Buzzer loudness level. Buzzer is switched off when 0 level is
selected
Key Press
Confirmation Signal
On Buzzer
Yes, No
When activated, button pressing is signalled with buzzer.