2
BKC-5000B Pre-Installation
Parts List
:
Anchor bolts x4
x4
Flat head phillips screws,
Cone point
Crimp connectors x12
Proximity key fob x1
Proximity EM cards x2
LED & Audible Indicators
1 Short beep
1 Long beep
2 Short beeps
3 Short beeps
Status
Audible Beeps
Key press
Valid access, Reset is completed
Login completed
Invalid access, Forget to press #
after entering passcode within
30 seconds
Constant beeping
Blue Power on, Standby mode
Green Unlocked, Door always unlocked
Red Invalid access, Door always locked
Status
LED
Bluetooth device vandalized,
Door sensor is on
BKC-5000B Wiring Diagram
(BKC-5000B have same wiring and pin setting)
Buzzer
Cable
Green
Brown
Green
Brown
Yellow
White
Blue
Black
Red
Orange
Orange
RTE (Request-To-Exit)
RTE (Request-To-Exit)
DS (Door Sensor)
DS (Door Sensor)
COM
ALM (Alarm Output)
ALM (Alarm Output)
(Polarity
(Polarity
Insensi ve)
Insensi ve)
V- (Power Supply)
V+ (Power Supply)
(Fail-Secure Electri
fi
ed Lock)
NO
(Fail-Safe Electri
fi
ed Lock)
NC
: Normal
(P
1,
P
2
)
P
1
P
2
P
3
Jumper Pin Setting :
: Reset
P
1
P
2
P
3
(P
2,
P
3
)
(Default)
P
1
P
2
P
3
1. Power off Access Control Reader.
2. Move the Pin Jumper to P2 and P3, then power on.
3. Hear a long beep to complete resetting procedures.
4. Move the Pin Jumper back to P1 and P2 to Normal setting.
5. Login as Admin and check all users, audit trail events are all cleared and everything is reset to factory
default setting, except device name.
Reset Procedures
Three-point security screw x1
Copyright All Rights Reserved ROFU Security International Corp. ROFU BKC-5000B. Published: 2018.09.11
Three-point screwdriver x1
(special tool)