Polilight Flare Plus 2 manual –
10
INTRODUCTION
The Polilight Flare+2 produces powerful narrow bands of light at wavelengths between 350 nm and
670 nm. The various coloured heads of the Flare+2 have been selected to facilitate various forensic
applications. They are suitable for all fingerprint and other trace evidence detection techniques and can
be used in three different ways to detect and enhance forensic evidence:
Fluorescence (Photoluminescence) imaging.
Reflection imaging using specular and diffused reflection.
Absorption imaging.
FILTER
400 - 750 nm
365 nm
WHITE LIGHT BAND
GENERAL SEARCHING,
FOOTPRINTS
GENERAL SEARCHING,
STAINS, FINGERPRINTS
ULTRAVIOLET BAND
415 nm
BLOOD PRINTS, SPLATTER,
GUNSHOT RESIDUE
VIOLET (BLOOD FILTER)
450 nm
GENERAL SEARCHING,
(SEMEN, UREA, FIBRES)
BLUE
505 nm
SUPERGLUE AND NINHYDRIN
TREATED PRINTS
BLUE / GREEN
530 nm
DFO TREATED PRINTS,
BACKGROUNG REDUCTION
GREEN
545 nm
DFO TREATED PRINTS,
BACKGROUNG REDUCTION
GREEN / YELLOW
620 nm
NINHYDRIN TREATMENTS,
BACKGROUND REDUCTION
ORANGE / RED
Figure 3. Polilight Flare+2 and Applications
LIGHT APPLICATIONS