MOUNTING THE AIR CAP TO THE AIR BODY
Be sure the Air Cap is fully sub-assembled before mounting it to the Air Body.
Place another air body gasket on the Air Body and align to the edges. Place the
Air Cap on the Air Body with the Air Regulator adjusting knob in plane with the
DO-3 pad on the hydraulic body.
D.
FINAL ASSEMBLY
Align the bottom faces of and tie down the Air Cap through the Air Body and
Ratio Plate to the Hydraulic Body using the four mounting bolts (5/16-18 x 4 ½'')
and lock-washers. Snug the bolts using a cross pattern.
Connect a temporary air supply to the pump (NO OIL YET) and be sure the air
regulator is turned out fully (CCW). Slowly turn in (CW) the air regulator until the
pump barely reciprocates. Then, while running, torque all eight Air Body bolts to
approx. 20 ft/lb. using a cross pattern. If the pump stalls or binds during torquing,
remove all air pressure, loosen all eight bolts and restart the procedure.