background image

FC-90 PLUS SERIES

FEEDER BOWL/HOPPER INTERLOCK

12

9

SWITCH

12

10

5

FC-40 PLUS SERIES TERM STRIP TB-2, INPUT

8

B)

TERM STRIP TB-2, OUTPUT

12

10

PADDLE

8

5

8

9

6

See section 6 of for the FC-40 Plus Series

models for more information.

10

6

LOW CURRENT

SWITCH

6

7

9

7

11

5

J1

7

11

A)

-

OFF/ON CONTROL GUIDE

+

OFF/ON CONTROL

FC-40 PLUS SERIES TERM STRIP TB-2

11

5-30 VDC INPUT VOLTAGE

FC-40 PLUS SERIES TERM STRIP TB-2

1

3

2

(DC Voltage from PLC or FC-90 Plus)

C)

LOW VOLTAGE INPUT SWITCHING

6

11

Fuses

8

8

12

60

SW3

SW5

External

SW4

-

+

JUMPER

2

5

9

11

4

10

7

7

12

3

1

6

9

10

5

LO A D

G

P/N 24-211

(SMALL)

A C   HO T

FC-40 PLUS

+

Pot Input

AUX FEATURE

A C  C O MMO N

TB2

120

TERM. STRIP

TB2

J1

4 -2 0 mA

+

-

-

S1

TB1

Direct

RUN

Interlock

RUN

H1

Mi

n

So

ft

Ma

x

TRANSFORMER

60 Rev

1

GND

Vi
 #

2

0

Bl #14

LINE VOLTAGE

Wh

Bl
 #

1

4

Gn

Bl
 #

1

4

L1

L1

TRIAC

GND

Wh

L2

Bl

W
h

 #14

(TALL)

L2

INPUT POWER

B

l #14

OUTPUT POWER

Bl
 #

1

4

Gn

CHASSIS

Bl #14

O

r #14

A2

GATE

TERM. STRIP

POWER

TB1

Bl

A1

Sig.

SIG

cw

-

+

100K

PO T

C O NTRO L

1/8W MIN

MA IN

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
 
 
 
 

 

RODIX INC. 

FEEDER CUBE

 

FC-40

 

Plus Series

 

WIRING DIAGRAM 

General Purpose and Open Frame 

208-240 Volt Connections

 

 

RODIX, INC.

 

2316 23

rd

 Ave., Rockford, IL  61104 

Toll Free (800) 562-1868, FAX (815) 316-4701

 

Email [email protected] 

www.rodix.com 

 

24-210 24-211 Board App Note 5/31/2012 Page 4 

Oil Resistant 208-240 Volt Connections

 

B

L

 #14

INPUT

INTERLOCK

GND

COM

HOT

INPUT POWER

CHASSIS

COM

HOT

GND

J1

MAIN TERMINAL

Torque to 9 in. lbs.

Customer supplied wiring

is shown by dashed lines.

OUTPUT POWER

11

6

8

8

12

60

SW3

External

SW5

-

SW4

+

2

5

11

9

4

7

10

7

3

12

6

1

9

5

10

LOAD

LINE VOLTAGE

G

TRIAC

TERM. STRIP

P/N 24-211

(SMALL)

AC HOT

FC-40 PLUS

A1

FUSE

GATE

+

Pot Input

AUX FEATURE

AC COMMON

TB2

120

TERM. STRIP

TB2

(TALL)

A2

4-20mA

TB1

+

-

-

S1

TB1

Or #14

B

l #14

B

L

 #14

B

l #14

Bl #14

V

i #20

RUN

Direct

Interlock

H1

Soft

Min

Max

60 Rev

TRANSFORMER

1

Sig.

SIG

-

cw

+

100K

1/8W MIN

CONTROL

POT

MAIN

5

7

2

6

3 4

1

POWER

Bl #14

Reviews: