42
•
EXPRESSION (OFF/EXP/VOL; see Expression on page 36)
These settings are temporary and are lost when the organ is turned off unless they are saved.
Note: A
MIDI Sav
e may be performed to save a MIDI setting as the default. See MIDI Save on
page 42. Instead of saving, you may press and hold (0) and momentarily press SET to return
MIDI couplers to their last saved status. This also returns Voice Palette selections of stop tabs to
their defaults.
MIDI Settings on Combination Pistons
After additional MIDI settings have been selected on a MIDI coupler piston, these settings can
be saved on any General or corresponding Divisional combination piston.
Saving MIDI Settings on a Combination Piston
1. Select the MIDI coupler piston (and organ stops, if desired).
2. Press and hold the SET piston.
3. Press the desired combination piston.
4. Release both pistons.
The factory default settings for the MIDI coupler pistons are:
MIDI GT A = CH 1
Program Change = OFF
MSB = 0
LSB = 0
Octave Transpose = NORM
Velocity = 64
Sustain = OFF
Reverb = 0
Chorus = 0
Expression = VOL
Note: See the MIDI channel list in
MIDI Channel Assignments
on page 31.
Remember, MIDI default settings can be saved by performing a MIDI Save procedure.
MIDI Save
Changes made to MIDI settings are temporary and are lost when the organ is turned off (these
changes can be saved to a piston as described above) unless those settings are saved. This is
done by performing the following procedure.