3.3
Environmental rating
3.3.1 MIL-STD-810
Item
Criteria
Humidity
According to MIL-STD-810G, Method 507.5, Procedure II
Figure 507.5-7, Table 507.5-IX
Operating: (Aggravated) 24 hours/cycle, total
of 10 cycles Between 30°C (86°F) and 60°C
(140°F) with the relative humidity at 95%
constant)
Vibration
According to MIL-STD-810G, Method 514.6, Procedure I
Category 24
According to MIL-STD-810G, Method 514.6, Procedure I
Category 20 Ground Vehicles
Operating: see Figure. 514.6C-3 und table
514.6C-VII
Shock
According to MIL-STD-810G, Method 516.6
Non-Operating: see Figure. 516.6-10, table
516.6-II, 40g, 11ms, saw tooth shock pulse
Temperature
According to MIL-STD-810G, Method 501.5 und 502.5,
Procedure I, II
Operating -20°C to +55°C
Non Operating: -40°C to +71°C
Table 8: MIL-STD-810
Note: Other certifications possible on request