6
Eastwood Technical Assistance: 800.343.9353 >> [email protected]
To order parts and supplies: 800.343.9353 >> eastwood.com
3
READ INSTRUCTIONS
• Thoroughly read and understand these product instructions before using
this tool. Failure to follow all warnings can result in tool damage or serious
physical injury.
• Save for future reference.
EYE INJURY HAZARD!
• Rapidly rotating surfaces can eject metal particles, dirt and debris at
high velocity. Always wear ANSI approved eye protection when operating
this tool.
HEARING DAMAGE HAZARD!
• This Rockwood Pneumatic Tool emits high sound levels while operating.
Use ANSI approved ear protection when operating.
BURSTING HAZARD!
• Do not exceed 90 psi (6.3 bar) of tool inlet pressure. Permanent tool damage
and/or explosion could occur and cause personal injury.
INJURY HAZARD
• This tool has high-speed, rotating components which can quickly cause
severe injury. Keep fingers and hands away from moving parts when
operating. Wear thick, well-fitting work gloves and keep loose clothing,
sleeves, cords, jewelry and hair away from moving parts.
INJURY HAZARD
• This tool could eject sparks at high speed which can ignite flammable
materials or injure others nearby. Do not operate near flammable materials
and keep all persons and pets away from the work area.
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION used with the safety alert symbol, indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury.
NOTICE is used to address practices not related to personal injury.
SAFETY INFORMATION
The following explanations are displayed in this manual, on the labeling, and on all other information
provided with this product:
PROBLEM
CAUSE
SOLUTION
Tool doesn’t
respond to trigger
depression
Insufficient volume
of air (CFM) to
operate tool
Verify sufficient air supply to tool.
(4 CFM @ 90 PSI minimum requirement)
Moisture or other
contamination in
air supply
Check for moisture in air line
and tool air inlet
Tool performance
is slow or sluggish
Insufficient volume
of air (CFM) to
operate tool
Verify sufficient air supply to tool.
(4 CFM @ 90 PSI minimum requirement)
Moisture or other
contamination in
air supply
Check for moisture in air line
and tool air inlet
Air Motor is lacking
lubrication
Stop use immediately and add air tool oil
directly to air inlet
Tool is excessively
noisy/emits high
pitched sound
Air Motor is lacking
lubrication
Stop use immediately and add air tool oil
directly to air inlet
Tool vibrates
excessively
during use
Loose Chuck Jaws
Tighten Chuck Jaws
Out of balance
condition from
damaged Chuck
Stop use immediately, check for damaged
Chuck
Out of balance
condition from
damaged drill bit
or accessory
Stop use immediately, replace damaged
drill bit or accessory
TROUBLESHOOTING