Troubleshooting
4-3
Table 4.A Fault Types, Descriptions and Actions
Manually Clearing Faults
Step
Key(s)
1. Press Esc to acknowledge the fault. The fault information will be
removed so that you can use the HIM.
2. Address the condition that caused the fault.
The cause must be corrected before the fault can be cleared.
3. After corrective action has been taken, clear the fault by one of
these methods.
•
Press Stop
•
Cycle drive power
•
Set parameter 240 [Fault Clear] to “1.”
•
“Clear Faults” on the HIM Diagnostic menu.
Esc
Fault Descriptions
Fault
No.
Type
(1)
Description
Action
Analog In Loss
29
➀
➂
An analog input is configured to
fault on signal loss. A signal loss
has occurred.
Configure with [Anlg In 1, 2 Loss]
on
1. Check parameters.
2. Check for broken/loose
connections at inputs.
Anlg Cal Chksum 108
The checksum read from the
analog calibration data does not
match the checksum calculated.
Replace drive.
Auto Rstrt Tries
33
➂
Drive unsuccessfully attempted
to reset a fault and resume
running for the programmed
number of [Flt RstRun Tries].
Enable/Disable with [Fault Config
1] on
.
Correct the cause of the fault and
manually clear.
AutoTune Aborted 80
Autotune function was canceled
by the user or a fault occurred.
Restart procedure.
Auxiliary Input
2
➀
Auxiliary input interlock is open.
Check remote wiring.
Decel Inhibit
24
➂
The drive is not following a
commanded deceleration
because it is attempting to limit
bus voltage.
1. Verify input voltage is within drive
specified limits.
2. Verify system ground impedance
follows proper grounding
techniques.
3. Disable bus regulation and/or
add dynamic brake resistor and/
or extend deceleration time.
Drive OverLoad
64
Drive rating of 110% for 1 minute
or 150% for 3 seconds has been
exceeded.
Reduce load or extend Accel Time.