background image

Wiring Diagrams

Micro800 Non-isolated Unipolar Analog 
Output Plug-in Module

Catalog Number 2080-OF2

http://literature.rockwellautomation.com/idc/groups/literature/documents/wd/208
0-wd004_-mu-p.pdf

FR

Cette publication est disponible en français sous forme électronique (fichier PDF). 
Pour la télécharger, rendez-vous sur la page Internet indiquée ci-dessus.

IT

Questa pubblicazione è disponibile in Italiano in formato PDF. Per scaricarla 
collegarsi al sito Web indicato sopra.

DE

Diese Publikation ist als PDF auf Deutsch verfügbar. Gehen Sie auf die oben 
genannte Web-Adresse, um nach der Publikation zu suchen und sie 
herunterzuladen.

ES

Esta publicación está disponible en español como PDF. Diríjase a la dirección web 
indicada arriba para buscar y descarga esta publicación.

PT

Esta publicação está disponível em portugués como PDF. Vá ao endereço web que 
aparece acima para encontrar e fazer download da publicação.

ZH

ZC

KO

Summary of Contents for Micro800

Page 1: ...esta pubblicazione è disponibile in Italiano in formato PDF Per scaricarla collegarsi al sito Web indicato sopra DE Diese Publikation ist als PDF auf Deutsch verfügbar Gehen Sie auf die oben genannte Web Adresse um nach der Publikation zu suchen und sie herunterzuladen ES Esta publicación está disponible en español como PDF Diríjase a la dirección web indicada arriba para buscar y descarga esta pu...

Page 2: ...prevent or minimize the spread of flame complying with a flame spread rating of 5V A V2 V1 V0 or equivalent if non metallic The interior of the enclosure must be accessible only by the use of a tool Subsequent sections of this publication may contain additional information regarding specific enclosure type ratings that are required to comply with certain product safety certifications In addition t...

Page 3: ...binés dans un système le code de température le plus défavorable code de température le plus faible peut être utilisé pour déterminer le code de température global du système Les combinaisons d équipements dans le système sont sujettes à inspection par les autorités locales qualifiées au moment de l installation WARNING EXPLOSION HAZARD Do not disconnect equipment unless power has been removed or ...

Page 4: ...ility in residential and other environments due to conducted and radiated disturbance Be careful when stripping wires Wire fragments that fall into the controller could cause damage Once wiring is complete make sure the controller is free of all metal fragments before removing the protective debris strip Do not wire more than 2 conductors on any single terminal If you insert or remove the plug in ...

Page 5: ...s to insert and secure the plug in module to the controller 1 Position the plug in module with the terminal block facing the front of the controller as shown 2 Snap the module into the module bay 3 Using a screwdriver tighten the 10 12 mm 0 39 0 47 in M3 self tapping screw to torque specifications 1 2 3 4 1 2 3 4 B A Back Front 40514 View into terminal block Pin A1 COM Pin B1 VO 0 Pin A2 COM Pin B...

Page 6: ...ed copper wire rated 90 C 194 F insulation max Voltage resistive load min 1 kΩ Current resistive load max 500 Ω Output voltage range 0 10V Output current range 0 20 mA Power consumption 60 mA 24V Temperature operating IEC60068 2 1 Test Ad Operating Cold IEC60068 2 2 Test Bd Operating Dry Heat IEC 60068 2 14 Test Nb Operating Thermal Shock 20 65 C 4 149 F Temperature surrounding air max 65 C 149 F ...

Page 7: ...L File E334470 CE European Union 2004 108 EC EMC Directive compliant with EN 61326 1 Meas Control Lab Industrial Requirements EN 61000 6 2 Industrial Immunity EN 61000 6 4 Industrial Emissions EN 61131 2 Programmable Controllers Clause 8 Zone A B European Union 2006 95 EC LVD compliant with EN 61131 2 Programmable Controllers Clause 11 C Tick Australian Radiocommunications Act compliant with AS NZ...

Page 8: ...n getting your product up and running New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures Allen Bradley Rockwell Automation Micro800 and TechConnect are trademarks of Rockwell Automation Inc Trad...

Reviews: