394
Rockwell Automation Publication 1783-UM007F-EN-P - September 2016
Chapter 8
Monitor the Switch
Trends
In Device Manager, you can view historical data to help you to analyze traffic
patterns and to identify problems. Data can be displayed in increments of
seconds, minutes, hours, or days.
To view the data in a table, click the Grid Mode button below the area. To
display a chart, click the Chart Mode button. Use the 60 s, 1 h, 1 d, and 1 w
links to display the data in increments of 60 seconds, 1 hour, 1 day, or 1 week.
From the Monitor menu, choose Trends.
Table 108 - Trends Graphs
Graph
Description
Bandwidth Utilization
The Bandwidth Utilization graph indicates the percentage of the available bandwidth that was used. The graph can show the bandwidth usage
patterns over incremental instances in time (by 60 seconds, 60 minutes, 24 hours, or 14 days). This graph also marks the highest peak reached. The
default is 60 seconds.
You can use this data to determine when network usage is high or low.
Packet Error
The Packet Error graph shows the percentage of packet errors that are collected over incremental instances in time (by 60 seconds, 60 minutes,
24 hours, or 14 days). The default is 60 seconds.
Use this graph to audit the effect that connected devices have on the switch performance or the network. For example, if you suspect that a
connected device is sending error packets, you can verify if the data on the graph changes when you disconnect and reconnect the device.
Port Utilization/Errors
The Port Utilization/Errors graph shows the usage patterns of a specific port over incremental instances in time by 60 seconds, 60 minutes, 24
hours, or 14 days. The default is 60 seconds.
To display the trends for a specific port, choose a port from the Port list.
Use these graphs to observe the performance of a specific port. For example, if a network user is having intermittent network connectivity, use the
Port Utilization graph to observe the traffic patterns on the port to which the computer is connected. You can also use the Port Errors graph to see
if the port is receiving or sending error packets.
PoE Utilization
For PoE switches, the PoE Utilization graph shows the power that is allocated to the connected devices.
Summary of Contents for ArmorStratix 5700 series
Page 12: ...12 Rockwell Automation Publication 1783 UM007F EN P September 2016 Table of Contents Notes...
Page 14: ...14 Rockwell Automation Publication 1783 UM007F EN P September 2016 Preface Notes...
Page 16: ...16 Rockwell Automation Publication 1783 UM007F EN P September 2016 Summary of Changes Notes...
Page 486: ...486 Rockwell Automation Publication 1783 UM007F EN P September 2016 Appendix A DataTypes Notes...
Page 547: ......