Rockwell Automation Publication 1783-UM007F-EN-P - September 2016
391
Monitor the Switch
Chapter 8
Port Status
In the navigation pane, click Port Status.
You can monitor alarms, statuses, thresholds, and bandwidth utilization for
each switch port. You can also access port and cable diagnostics.
Table 106 - Port Status Fields
Field
Description
Unit
(Stratix 8000/8300 switches)
Indicates where the port resides:
• Base (for example, 1783-MS10T).
• Expansion module (for example, 1783-MX08T).
Port
Displays the selected port. The port number includes the port type (Fa for Fast Ethernet and Gi for Gigabit Ethernet) and the specific port number.
EXAMPLE:
Gi1/1 is Gigabit Ethernet port 1.
Port Alarm Status
Displays the status of the port alarm.
Valid values:
• Link fault alarm
• Port not forwarding alarm
• Port not operating alarm
• High bit error rate alarm
• No alarms
Link Status
Displays whether the link is active or inactive.
Port Fault Status
Displays the status of the port alarm.
Valid values:
• Error - Disable event
• SFP error - Disabled
• CDP native VLAN mismatch
• MAC address flap
• Port security violation
• No fault
Summary of Contents for ArmorStratix 5700 series
Page 12: ...12 Rockwell Automation Publication 1783 UM007F EN P September 2016 Table of Contents Notes...
Page 14: ...14 Rockwell Automation Publication 1783 UM007F EN P September 2016 Preface Notes...
Page 16: ...16 Rockwell Automation Publication 1783 UM007F EN P September 2016 Summary of Changes Notes...
Page 486: ...486 Rockwell Automation Publication 1783 UM007F EN P September 2016 Appendix A DataTypes Notes...
Page 547: ......