Operating the dispenser

 

1.

 Insert 

2

 “C” cell alkaline batteries (not included). 

 

2.

 Press the female end of the green actuator adapter onto the top of the cartridge. Six  

 

    actuators are included in each case of cartridges.

 

3.

 Slide the cartridge into the dispenser while pressing both the cartridge and green  

 

    adapter securely into place. You should hear a “beep” once the cartridge is securely in  

 

    place.

 

4.

 Press the 

RED POWER

 button. The display will appear in the LCD screen.

 

5.

 Press the 

BLACK ENTER

 button to cycle the dispenser until you see liquid exit  

                the bottom of the dispenser, just below the nut (you may have to press the enter  

 

    button up to 15 times).

 

6.

 Press the 

GREEN QUICK

 button until the LCD displays 

30

, indicating the    

 

    dispenser is set for a 

30

 day cycle. This will cycle the unit approximately every 

 

    14 minutes.

 7.  Close the cover to lock the dispenser unit. 

  

8.  

WARNING:

 If an alarm sounds check to make sure the green actuator adapter is  

 

   firmly in place, batteries are placed properly and the cartridge is securely in place. 

 

    

Monthly Service – Changing the Cartridge

 

1.

 Replace the cartridge monthly by removing the old cartridge (with the green adapter  

 

    attached) and place the existing (or new) green adapter onto the new cartridge.  

 

    Follow the instructions above in “Operating the dispenser” section 

E3-E7

.

 

2. 

Check the drip tube to ensure it has not come loose and is still secure at the    

 

    injection point. 

 

3. 

Check the drip tube to ensure there are no blockages. If necessary replace the drip  

 

    tube. 

 

4. 

Replace batteries twice a year or as needed. Each time batteries are replaced the  

                

GREEN QUICK

 

button must be pressed until the LCD displays 

30 

to reset the  

 

    timer.  

E6

 Quick Button

    (Programming Options)

E5

 Enter Button

(Quick Cycles)

E4

 Power Button

    (Turns unit on and off)

Placement considerations:

• To avoid water damage and possible malfunction, the 

Power Dose

 units should be installed          

  outside splash zones. 

   In order for the 

Power

 

Dose

 unit to achieve optimal results, it should be installed in drain lines  

  with daily water flow.

 DO NOT treat dishwasher drain lines for 

8-10

 ft from the dishwasher. Most are   

  

140°

 or higher and will liquify grease and keep the drain line clear.

 If there is a FOUL ODOR coming from the grease trap – Place an InVade Bio Bullet  

 

  into the trap. If the trap cannot be opened, do an initial treatment of the drain with  

 

  InVade Bio Foam, InVade Bio Drain or InVade Hot Spot.

D6

D

E2

Closed Drain Installation

E3

2