Mounting the Sensor

Securely mount the sensor on a firm, stable surface or support. An 
application subject to excessive vibration or shifting may cause 
intermittent operation. For installation convenience, Rockwell 
Automation offers a wide range of mounting brackets (see 
Accessories section for more detail).

Note:

Due to the detection method, targets travelling 
horizontally to the sensor’s optics are detected. Targets 
travelling vertically may not be accurately detected. For 
reliable background suppression, a minimum separation 
distance is recommended between the target and the 
background; however this can vary depending on the 
application. Refer to the Typical Response Curves section.

VisiSight™ Configuration

The 42JT VisiSight is configured using the push button or Remote 
Teach or via IO-Link, and the LED indicators on the sensor. Four 
features can be configured:

• Standard or precision teach for sensitivity/sensing range
• Light operate (LO) or dark operate (DO) output
• Auto PNP/NPN, dedicated NPN or dedicated PNP
• Push button lock/unlock

The sensor output is disabled during Teach.

Teach Sensitivity/Sensing Range

The default setting is the maximum sensitivity/range.
Teaching the sensitivity/sensing range is a two-step process: 
teach the background (first condition) and teach “target” (second 
condition). Switching threshold for output ON vs. OFF is set in 
between the two conditions. 

Standard Teach:

1. To teach the background (first condition):

2. Teach “target” (second condition):

Align the sensor to the background. Press and 

hold button for three seconds until yellow LED 

starts flashing. Release the button. The first 

condition has now been taught.

In the case of multiple reflectivity targets, 

choose the darkest/least reflective target 

placed in its farthest position for set up.

Target

t > 3 s

Background

IMPORTANT

If there’s no background surface in the field of view in Step 1, the 
switching threshold will be set between the distance to the target 
and the maximum sensing range. 

The sensor can also be taught 

by teaching the target as the first condition and background 

as the second condition.
Precision Teach:

 For a more precise setting with a smaller 

hysteresis, teach the sensor to the target in step 1 and keep the 
target present in step 2).

Restore to factory default setting of maximum range:

 Perform 

steps 1 and 2 with “no target” in the sensor’s field of view and 
nothing in the background.

Teach Light Operate (L.O.) or Dark Operate (D.O.)

The default setting of the output is Light Operate (L.O.)
L.O. setting means that output turns ON when the target is 
detected. If the application requires the output to turn OFF when 
the target is detected, the setting may be changed to Dark 
Operate (D.O.).

1. To access the teach output mode setting:

2. To change the sensor output mode setting:

Output Type Selection: Auto PNP/NPN, Dedicated NPN, 

Dedicated PNP

The default setting is Auto PNP/NPN. The sensor monitors the 
load connection and automatically configures for proper 
operation, i.e. PNP or NPN. If no load is connected, the sensor 
defaults to PNP. The following applications are covered with 
dedicated PNP or dedicated NPN selection:

a. Parallel wiring of multiple sensor outputs: select dedicated 

PNP or dedicated NPN setting, as needed.

Insert the target between the sensor and the 

background. Press and release the button. The 

teach process is complete. 

If the push button is not pressed within 30 

seconds, the sensor exits teach mode and returns 

to RUN mode without learning the new setting.

Press and hold button for six seconds until the 

green LED starts flashing. Release the button. The 

current setting is indicated by the yellow LED:

L.O.: Yellow LED ON

D.O.: Yellow LED OFF

Press and release the button within ten seconds to 

toggle from L.O. to D.O., the selection indicated by 

the yellow LED.

The sensor retains the setting per the last button 

depression and returns to the RUN mode ten 

seconds after the last button is depressed.

t < 0.5 s

Target

Background

t > 6 s

t < 0.5 s