3-88
Programming and Parameters
PowerFlex 700S Phase II AC Drive User Manual -
Publication 20D-UM006G-EN-P – July 2008
731
PLL Posit Out
Phased Locked Loop position output. This signal is precisely in phase with the input physical
device. A link should be made to it from the local drive auxiliary position input. (The local drive
is the one implementing PLL.)
Note: This parameter was added for firmware version 3.01.
Default:
Min/Max:
0
-/+2147483648
RO 32-bit
Integer
732
PLL Posit OutAdv
Phased Locked Loop position advanced output. This signal is one position sample in advance
of
[PLL Posit Out]. A link is normally made to this parameter from SynchLink.
Note: This parameter was added for firmware version 3.01.
Default:
Min/Max:
0
-/+2147483648
RO 32-bit
Integer
733
PLL FiltPositOut
Phased Locked Loop internal low pass filter output. This parameter is normally used to
properly scale an external velocity reference. See description of
[PLL Ext SpdScale].
Note: This parameter was added for firmware version 3.01.
Units:
Default:
Min/Max:
P.U.
0.0
-/+2200000000.0
✓
RW Real
734
PLL Speed Out
Phased Locked Loop velocity output. This signal is used as a velocity feed forward. It is
precisely in phase with the physical input device. A link should be made to it from one of the
inputs on the local drive. (The local drive is the one implementing PLL.) The 1 pu RPM of this
parameter is set by
[PLL VirtEncdrRPM].
Note: This parameter was added for firmware version 3.01.
Units:
Default:
Min/Max:
P.U.
0.0
-/+2200000000.0
✓
RW Real
735
PLL SpeedOut Adv
Phase Locked Loop velocity advanced output. This signal is one velocity reference sample in
advance of
[PLL Speed Out]. A link is normally made to this parameter from
SynchLink. (Velocity reference is performed in the same task as the position regulator.)
Note: This parameter was added for firmware version 3.01.
Units:
Default:
Min/Max:
P.U.
0.0
-/+2200000000.0
✓
RW Real
737
Posit TP Select
Enter or write a value to select position regulator data displayed in
[PositTP DataInt]
[PositTP DataReal].
Default:
Options:
0 =
0 =
1 =
2 =
3 =
4 =
5 =
6 =
7 =
8 =
“Zero”
“Zero”
9 = “Limiter Out”
“del Xos Vout”
10 = “Ref EGR In”
“del Xcmd”
11 = “OffsetSpdLim”
“del Act Load”
12 = “Pt-Pt SpdLim”
“del Act Mtr”
13 = “Sec per Edge”
“Integ Error”
14 = “Edge per Sec”
“Xprop Out”
15 = “Ratio Guess”
“Fdbk Sel Alt”
16 = “Sync Count”
“PreLim Xvout”
738
PositTP DataDInt
Displays the integer data selected by
[Posit TP Select]. This display should only be
used if the selected value is Integer data.
Default:
Min/Max:
0
-/+2147483648
RO 32-bit
Integer
739
PositTP DataReal
Displays the real data selected by
[Posit TP Select]. This display should only be used
if the selected value is Real data.
Default:
Min/Max:
0.0
-/+8.0 pu
RO Real
No.
Name
Description
Values
Linkab
le
R
ead-Wr
ite
Da
ta
T
ype