Installation
Node Controller Installation
Node Controller Hardware User Manual
95
Rockwell Automation Publication MMI-UM013B-EN-P - April 2020
Mounting NC LITE Node Controllers
Locate the NC LITE close to the nodes it is responsible for to minimize the length of all wir-
ing. The node controller can be oriented in any direction that is required, make sure that the
service and exclusion zones that are identified in
are maintained.
Surface Mounting
Typical methods for mounting the NC LITE on the mounting plate are shown in
.
See
Figure 5-8: NC LITE Surface Mounting
1.
Install the mounting flanges onto the NC LITE, if not already installed.
2.
Orient the NC LITE on the mounting plate as required and secure it to the plate with
two M5 x 10 mm screws with Loctite 243. Tighten the screws to 2.7 N•m [24 in•lb].
NOTE:
The Loctite must cure for 2 hours at 22° C [72° F] before using the transport
system.
3.
Orient the bracket with the node controller as required and secure it with two M8
screws with M8 split lock washers. Tighten the screws to 26 N•m [230 in•lb]. Make
sure that the service and exclusion zones are maintained.
4.
Install cable management as required to secure the cables that are connected to the
node controller.
PW
R
LAN
18 V
DC
Po
E O
N
LY
M5 Screw
(2X)
Mounting Flange
(2X)
Mounting Plate