Specifications and Site Requirements
Electrical Specifications
78
MagneMotion
Rockwell Automation Publication MMI-UM013B-EN-P - April 2020
NC LITE
7–18V DC, 5 W max based on configuration and operating mode. See
for the mechanical drawing.
AC Power Option
The optional remote power supply for the NC LITE requires 90–264V AC @ 47–63 Hz, sin-
gle-phase (phase-to-phase or phase-to-neutral), 0.7 A at 100V AC (25 W max). Inrush current
45 A/240V AC max The actual power being drawn depends on the operations being per-
formed. However, all power wiring must be designed to carry the full load. See the data sheet
provided by the power supply manufacturer for mechanical information.
AC Power Cable
The optional remote power supply for the NC LITE is supplied with a power cable. Contact
MagneMotion for replacement cables. The AC power cable plugs directly into the power sup-
ply. The remote power supply and AC cable for the NC LITE is not required if Power over
Ethernet is being used.
DC Power Option
DC power from a user-supplied power supply requires 7–18V DC, 5 W.
The actual power being drawn depends on the operations being performed. Make sure that all
power wiring can carry the full load and has a limited power source or the power source is
fused to the maximum rating of the wiring.
Or, power for the NC LITE can be provided using the MagneMotion custom Power over
Ethernet network. The remote power supply is not required in this case.
CAUTION
High-Voltage Hazard
90–264V AC, 25 W
AC power must be disconnected before servicing.
NOTICE
Any user-supplied power supply must be NRTL/ATL approved.