Appendix C Specifications
The maximum drive-to-motor cable length depends on the input power and
feedback type. However, if flying lead cables were used on the Ultra3000 drive,
the feedback connector kit needs to be replaced by 2198-K53CK-D15M feedback
connector kit, as it is required for Kinetix 5300 drives when flying lead cables
are used.
See the Kinetix Motion Accessories Technical Data, publication
for cable specifications.
Environmental
Specifications
This section provides the environmental specifications for the Ultra3000 and
Kinetix 5300 servo drives.
Ultra3000 Servo Drive Environmental Specifications
Kinetix 5300 Servo Drive Environmental Specifications
Specification
Operational Range
Storage Range (non-operating)
Ambient Temperature
0 °C…55 °C (32 °F…131 °F)
-35 °C…70 °C (-40 °F…158 °F)
Relative Humidity
5…95% noncondensing
5…95% noncondensing
Altitude
1500 m (4921.5 ft) - Derate 3% per 300 m (984.3 ft) above 1500 m (4,921.5 ft)
Vibration
5…2000 Hz @ 2.5 g peak, 0.0006 mm (0.015 in.) maximum displacement
Shock
15 g, 11 ms half-sine pulse
Attribute
Operational Range
Storage Range (nonoperating)
Ambient temperature
0…50 °C (32…122 °F)
-40…+70 °C (-40…+158 °F)
Relative humidity
5…85% noncondensing
5…95% noncondensing
Protection class (IEC 60529)
IP20
Degree of pollution
(IEC 61800-5-1)
2
Altitude
1000 m (3281 ft)
1000 m (3281 ft)
Vibration
5…55 Hz @ 0.35 mm (0.014 in.) double amplitude, continuous displacement;
55…500 Hz @ 2.0 g peak constant acceleration (ten sweeps in each of three
mutually perpendicular directions)
Shock
15 g, 11 ms half-sine pulse (three pulses in each direction of three mutually
perpendicular directions)