3-60
Programming and Parameters
APPLICA
T
ION
S
To
rque Pr
o
vi
n
g
601
[TorqProve Setup]
Allows control of specific torque proving functions through a communication
device.
602
[Spd Dev Band]
Defines the allowable difference between
the commanded frequency and encoder
feedback value. A fault will occur when
the difference exceeds this value for a
period of time.
Default:
Min/Max:
Units:
2.0 Hz
60.0 RPM
0.1/15.0 Hz
3.0/450.0 RPM
0.1 Hz
0.1 RPM
603
[SpdBand Integrat]
Sets the amount of time before a fault is
issued when [Spd Dev Band] is outside
its threshold.
Default:
Min/Max:
Units:
60 mSec
1/200 mSec
1 mSec
604
[Brk Release Time]
Sets the time between the brake release
command and when the drive begins to
accelerate. In Encoderless mode, this
parameter sets the time to release the
brake after drive starts.
Default:
Min/Max:
Units:
0.10 Secs
0.00/10.00 Secs
0.01 Secs
605
[ZeroSpdFloatTime]
Sets the amount of time the drive is
below [Float Tolerance] before the brake
is set. Not used in Encoderless
TorqProve mode.
Default:
Min/Max:
Units:
5.0 Secs
0.1/500.0 Secs
0.1 Secs
606
[Float Tolerance]
Sets the frequency level where the float
timer starts. Also sets the frequency level
where the brake will be closed in
Encoderless TorqProve mode.
Default:
Min/Max:
Units:
0.2 Hz
6.0 RPM
0.1/5.0 Hz
3.0/150.0 RPM
0.1 Hz
0.1 RPM
607
[Brk Set Time]
Defines the amount of delay time
between commanding the brake to be set
and the start of brake proving.
Default:
Min/Max:
Units:
0.10 Secs
0.00/10.00 Secs
0.01 Secs
608
[TorqLim SlewRate]
Sets the rate to ramp the torque limits to
zero during brake proving.
Default:
Min/Max:
Units:
10.0 Secs
0.5/300.0 Secs
0.1 Secs
609
[BrkSlip Count]
Sets the number of encoder counts to
define a brake slippage condition.
Default:
Min/Max:
Units:
250
0/65535
1
Fi
le
Gr
ou
p
No.
Parameter Name & Description
See
page 3-2
for symbol descriptions
Values
Relate
d
0
0
0
0
x
x
x
x
x
x
x
x
x
x
x
x
10
0
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1
=Enabled
0
=Disabled
x =Reserved
Bit #
Factory Default Bit Values
Fast Stop
Micr
o P
os
Decel Limit
End Stop
Summary of Contents for Allen-Bradley PowerFlex 700 B Series
Page 10: ...P 6 Overview Notes ...
Page 36: ...1 26 Installation Wiring Notes ...
Page 118: ...3 78 Programming and Parameters Notes ...
Page 162: ...A 28 Supplemental Drive Information Notes ...
Page 227: ......