4
S
Choose desired mode and slide set switch to RUN (settings
are now locked).
Setting Output Mode
Output Mode Options: Light On
Light On Off delay (40ms delay)
Dark On
Dark On Off delay (40ms delay)
S
Slide switch to SET position
S
Press and hold BLACK button for 3 seconds
S
The display will show “SELE”
Operating Mode
Frequency/Channel Indicator
S
Push the BLACK button until desired output is set
Light On
Light On
Off Delay
Dark On
Dark On
Off Delay
S
Slide switch to RUN
Setting Interference Protection
S
Slide switch to SET position
S
Press and hold BLACK button for 3 seconds
S
The display will show “SELE”
S
Push the RED button to select Channel 1 or 2 for
transmission frequency selection for prevention of
interference between 2 sensors
S
Set switch to RUN
Teaching the Sensor
Stationary Target
S
Slide switch to SET (flashing “T”)
S
Push and release RED button without target present
(Indicators flash to show standby status)
S
Push and release RED button with target in position
(Flashing indicators stop flashing)
S
Slide switch to RUN
S
Setting is complete
Moving Target
S
Slide switch to SET (flashing “T”)
S
Push and hold RED button (Orange and Green LED
flashing alternately)
S
While holding down RED button pass target in front of
sensor (LED flashing slows down)
S
Release RED button when target finishes passing sensor
S
Slide switch to RUN
S
Setting is complete
Transmitted Beam Setting
S
Set up opposing fibers
S
Block light with target
S
Slide switch to SET (flashing “T”)
S
Push RED button twice
S
Slide switch to RUN
S
Setting is complete
Sensitivity Adjustment (Absolute Sensing Mode)
S
Quickly flip switch from RUN to SET to RUN (“s” flashes to
show sensitivity adjustment status)
S
Push RED button to decrease sensitivity
S
Push BLACK button to increase sensitivity
S
Unit automatically enters locked condition 10 seconds after
completion of adjustment
Sensitivity Adjustment (Relative Sensing Mode)
S
Quickly flip switch from RUN to SET to RUN (“s” flashes to
show sensitivity adjustment status)
S
Push BLACK button to decrease sensitivity
S
Push RED button to increase sensitivity
S
Unit automatically enters locked condition 10 seconds after
completion of adjustment
Dimensions—mm (inches)
Receiver
Transmitter
9
(0.35)
5 (0.2)
4.7
(0.19)
3
(0.12)
30
(1.18)
9
(0.35)
4 (0.16)
60 (2.36)
3
(0.12)
3
(0.12)
4.8
(0.19)
Dia.
4 (0.16)
21 (0.83)
16
(0.63)
36.5 (1.44)
11.5
(0.45)
2-3.2 (0.13)
Dia. hole
2-3.2 (0.13) x 5.2
(0.2) oval hole
21 (0.83)
16
(0.63)
Mounting Bracket
Cord
Bushing
Replacement Parts
S
Plastic Sensor Cover: PSC1
S
Fiber Optic Cable (Diffuse/Retro): 99–94
S
Fiber Optic Cable (Transmitted Beam): 99–90
S
Pico QD Cordset: 889P–F4AB–2
S
Power Bus QD Connectors:
1 Conductor: 45F–A1C–A2
3 Conductor: 45F–A3C–A2
S
Power Bus End Caps:
Male Cap: 45F–AMC
Female Cap: 45F–AFC
S
1.25mm fiber optic adaptor: 61–6731
Publication 75009–138–01(B)
May 2002
Printed in USA
PHOTOSWITCH
R
is a registered trademark
of Rockwell Automation.