Rockwell Automation Allen-Bradley Photoswitch Bulletin 45FVL Series Installation Instructions Download Page 4

4

S

Choose desired mode and slide set switch to RUN (settings
are now locked).

Setting Output Mode

Output Mode Options: Light On

Light On Off delay (40ms delay)
Dark On
Dark On Off delay (40ms delay)

S

Slide switch to SET position

S

Press and hold BLACK button for 3 seconds

S

The display will show “SELE

Operating Mode

Frequency/Channel Indicator

S

Push the BLACK button until desired output is set

Light On

Light On

Off Delay

Dark On

Dark On

Off Delay

S

Slide switch to RUN

Setting Interference Protection

S

Slide switch to SET position

S

Press and hold BLACK button for 3 seconds

S

The display will show “SELE

S

Push the RED button to select Channel or for
transmission frequency selection for prevention of
interference between 2 sensors

S

Set switch to RUN

Teaching the Sensor

Stationary Target

S

Slide switch to SET (flashing “T”)

S

Push and release RED button without target present
(Indicators flash to show standby status)

S

Push and release RED button with target in position
(Flashing indicators stop flashing)

S

Slide switch to RUN

S

Setting is complete

Moving Target

S

Slide switch to SET (flashing “T”)

S

Push and hold RED button (Orange and Green LED
flashing alternately)

S

While holding down RED button pass target in front of
sensor (LED flashing slows down)

S

Release RED button when target finishes passing sensor

S

Slide switch to RUN

S

Setting is complete

Transmitted Beam Setting

S

Set up opposing fibers

S

Block light with target

S

Slide switch to SET (flashing “T”)

S

Push RED button twice

S

Slide switch to RUN

S

Setting is complete

Sensitivity Adjustment (Absolute Sensing Mode)

S

Quickly flip switch from RUN to SET to RUN (“s” flashes to
show sensitivity adjustment status)

S

Push RED button to decrease sensitivity

S

Push BLACK button to increase sensitivity

S

Unit automatically enters locked condition 10 seconds after
completion of adjustment

Sensitivity Adjustment (Relative Sensing Mode)

S

Quickly flip switch from RUN to SET to RUN (“s” flashes to
show sensitivity adjustment status)

S

Push BLACK button to decrease sensitivity

S

Push RED button to increase sensitivity

S

Unit automatically enters locked condition 10 seconds after
completion of adjustment

Dimensions—mm (inches)

Receiver

Transmitter

9

(0.35)

5 (0.2)

4.7

(0.19)

3

(0.12)

30

(1.18)

9

(0.35)

4 (0.16)

60 (2.36)

3

(0.12)

3

(0.12)

4.8

(0.19)

Dia.

4 (0.16)

21 (0.83)

16

(0.63)

36.5 (1.44)

11.5

(0.45)

2-3.2 (0.13)

Dia. hole

2-3.2 (0.13) x 5.2

(0.2) oval hole

21 (0.83)

16

(0.63)

Mounting Bracket

Cord

Bushing

Replacement Parts

S

Plastic Sensor Cover: PSC1

S

Fiber Optic Cable (Diffuse/Retro): 99–94

S

Fiber Optic Cable (Transmitted Beam): 99–90

S

Pico QD Cordset: 889P–F4AB–2

S

Power Bus QD Connectors:
1 Conductor: 45F–A1C–A2
3 Conductor: 45F–A3C–A2

S

Power Bus End Caps:
Male Cap: 45F–AMC
Female Cap: 45F–AFC

S

1.25mm fiber optic adaptor: 61–6731

Publication 75009–138–01(B)

May 2002

Printed in USA

PHOTOSWITCH

R

 is a registered trademark

of Rockwell Automation.