![Rockwell Automation Allen-Bradley MobileView 2711T-B10I1N1 Quick Start Manual Download Page 21](http://html1.mh-extra.com/html/rockwell-automation/allen-bradley-mobileview-2711t-b10i1n1/allen-bradley-mobileview-2711t-b10i1n1_quick-start-manual_1475897021.webp)
Rockwell Automation Publication 2711T-QS002C-EN-P - March 2019
21
Second Generation MobileView Tethered Operator Terminal
Illuminated E-stop Button Brightness
You can use a button on the IP65 junction box terminal to adjust the
illuminated E-stop push button on a second generation MobileView
terminal.
The following brightness levels can be selected.
Each press of the button moves to the next brightness level. After you reach 12.5% brightness,
the next press cycles back to 95%.
The set brightness level is maintained, even after a power loss.
Configure the 2711T-JBIP65DM1 Junction Box
The 2711T-JBI65MI junction box with M12 On-Machine connections is factory wired. It is still
shipped with the back plate removed, so you can configure Box ID functionality or adjust the
brightness of the illuminated push button on the MobileView terminal before you mount the
junction box to its back plate and connect the M12 On-Machine connections.
Box ID Functionality
See
for where to find the Box ID address switches on the junction box circuit
board.
See
for how to configure Box ID functionality for your 2711T-JBI65MI junction box.
WARNING:
To adjust the brightness, power must be applied to the IP65 junction box, and a
second generation MobileView terminal must be connected to the junction box.
To avoid ESD damage to the junction box and to avoid electrical shock to the adjuster, only
qualified personnel should perform this adjustment.
• 95% (factory setting)
• 25%
• 50%
• 12.5%
IMPORTANT
Only adjust the brightness level of the illuminated E-stop button if it is appropriate for the
environment where the second generation MobileView terminal is being used. Too low of a
brightness setting can be difficult to see or can be misinterpreted.
SHOCK HAZARD:
When the back plate is removed, the circuit board inside the 2711T-JBIP65DM1
junction box is sensitive to electrostatic discharge (ESD).
Use an antistatic wriststrap connected to the work surface, and properly grounded tools and
equipment.