Mounting Orientations
The Kinetix MMA main motors have multiple mounting orientations. The orientation is limited by the motor size and bearing type. Mounting with IM B5 and V3 is not feasible
for some sizes. Before any lifting or mounting operations occur, confirm the mounting orientation. For additional information, see
and
.
Figure 2 - Allowed Mounting Orientations
Functional Safety
Kinetix MMA main motors can be configured with a functional safety-rated encoder, and are designed in compliance with applicable safety standards and documentation. It
is the responsibility of the customer to select and configure the Kinetix MMA main motor to meet all Functional Safety requirements, per the Kinetix Rotary Motion
Specifications Technical Data, publication
and the drives manuals listed in the
. See
Catalog Number Explanation on page 4
for details
about each option. See
Motor Cat. No.
(1)
(1)
See
for permissible radial loads.
Stator Cat. No.
Horizontal Mounting
With Shaft Down
(2)
(2)
Only recommended with a ball bearing. Roller bearing and high speed bearing options are not recommended. Verify maximum permissible radial load.
With Shaft Up
Foot
Foot only
Flange Only
Support
Foot
Flange Only
Foot
Foot only
Flange Only
B35
B3
B5
B5+Su
V15
V5
V1
V36
V6
V3
MMA-B080
xxx
A, B, C
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
D, E
No
MMA-B100
xxx
A, B, C
Yes
D, E
No
MMA-B132
xxx
A, B
Yes
Yes
(3)
(3)
A vertical mounting option is recommended for mounting the motor with shaft up (flange options C, D, G, K).
Yes
Yes
C
No
D, E
No
MMA-B160
xxx
A, B
Yes
Yes
C, D
No
No
MMA-B180
xxx
A, B
Yes
C, D
No
MMA-B225
xxx
A, B
Yes
C, D, E
No
B 35
B 3
B 5
B 5 + support
V 15
V 5
V 1
V 36
V 6
V 3
Horizontal Mounting
Vertical Mounting