Publication 2094-UM001A-EN-P — September 2006
84
Connecting the Kinetix 6000 Drive System
Wiring the LIM Connectors
This section provides examples and wiring tables to assist you in
making connections to the line interface module (LIM) connectors.
Wiring the Auxiliary Input Power (APL) Connector
The Auxiliary Input Power (APL) connector is present only on the
2094-XL75S-C
x
models.
Line Interface Module (APL connector)
Auxiliary Input Power (APL) Connector
L2/N
L1
1 2
Line Interface Module, Top
V
iew
(2094-XL75
S
-C
x
is shown)
Single-phase Supply
APL Pin
Signal
Recommended
Wire Size
mm
2
(AWG)
Strip Length
mm (in.)
Torque Value
Nm (lb-in)
L1
1
L1
0.2-4.0
(24-10)
7.0
(0.28)
0.5 - 0.6
(4.4 - 5.3)
L2
2
L2/N