Planning the Kinetix 6000 Drive System Installation
37
Observe the following guidelines when installing your 1756-M
xx
SE
SERCOS interface module:
•
The clean zone (C) is beneath the less noisy modules (I/O, analog,
encoder, registration, etc. (grey wireway).
•
The dirty zone (D) is above and below the power supply and
noisy modules (black wireway).
•
The SERCOS fiber-optic cables are immune to electrical noise.
Establishing Noise Zones (ControlLogix)
Cable Categories for Kinetix 6000 Systems
The table below indicates the zoning requirements of cables
connecting to the Kinetix 6000 drive components.
Integrated Axis Module (converter side)
(1)
D
D
C
AC Line
Filter
Spare Slots
Dirty Wireway
Clean Wireway
Route dirty wireways directly above the ControlLogix rack
(shielded by the chassis).
Line Filter/Power Supply
Connections Segregated
(not in wireway)
Dirty I/O
(24V dc I/O, ac I/O)
Clean I/O
(Analog, Encoder
Registration)
Wire/Cable
Connector
Zone
Method
Very
Dirty
Dirty
Clean
Ferrite
Sleeve
Shielded
Cable
CTRL 1 and 2
CPD
X
DC-/DC+ (unshielded cable)
IPD
X
L1, L2, L3 (shielded cable)
X
X
L1, L2, L3 (unshielded cable)
X
CONT EN- and CONT EN+ (M1 contactor)
CED
X
DPI
DPI
X
X
Summary of Contents for Allen-Bradley Kinetix 6000
Page 8: ...Publication 2094 UM001A EN P September 2006 8 Table of Contents...
Page 18: ...Publication 2094 UM001A EN P September 2006 18 Start...
Page 118: ...Publication 2094 UM001A EN P September 2006 118 Connecting the Kinetix 6000 Drive System...
Page 190: ...Publication 2094 UM001A EN P September 2006 190 Specifications and Dimensions...
Page 265: ...Publication 2094 UM001A EN P September 2006 265 Notes...
Page 266: ...Publication 2094 UM001A EN P September 2006 266 Notes...
Page 267: ...Publication 2094 UM001A EN P September 2006 267 Notes...