Publication 2094-UM001A-EN-P — September 2006
DC Common Bus Applications
233
Kinetix 6000 Capacitance
Values
Use the tables below when calculating total bus capacitance and
additional bus capacitance for your Kinetix 6000 common bus
application.
IAM/AM (230V) Modules
IAM/AM (460V) Modules
SM (230/460V) Module
IAM Converter (230V)
Capacitance
µF
AM Inverter (230V)
Capacitance
µF
2094-AC05-MP5-S
270
2094-AMP5-S
390
2094-AC05-M01-S
2094-AM01-S
660
2094-AC09-M02-S
540
2094-AM02-S
780
2094-AC16-M03-S
1320
2094-AM03-S
1320
2094-AC32-M05-S
1980
2094-AM05-S
2640
IAM Converter (460V)
Capacitance
µF
AM Inverter (460V)
Capacitance
µF
2094-BC01-MP5-S
110
2094-BMP5-S
75
2094-BC01-M01-S
2094-BM01-S
150
2094-BC02-M02-S
220
2094-BM02-S
270
2094-BC04-M03-S
940
2094-BM03-S
840
2094-BC07-M05-S
1410
2094-BM05-S
1175
SM (230-460V)
Capacitance
μ
F
2094-BSP2
470