22
Rockwell Automation Publication 2093-AP001A-EN-P - May 2014
Chapter 2
Servo Drive and System Comparisons
AC Input Power Wiring and
Fusing
This section provides information to assist you in determining the wiring and
fusing requirements of the drives.
AC Input Power Wiring
Determining AC input wiring for the Kinetix 5500 servo drives will require
evaluation of which configuration is best for your system. The Kinetix 2000 servo
drive accepts AC input to the Integrated Axis Module (IAM) and converts the
AC power to DC and that is shared with the other connected Axis Modules
(AMs). The Kinetix 5500 servo drives are designed for multiple power
configurations. They can be wired independently (single axis) or in multi-axis
configurations, including:
•
Standalone
•
AC/DC Supply Sharing
•
DC Bus Sharing
•
Hybrid Configuration (consisting of shared AC/DC supply with DC bus)
Kinetix 2000 Servo Drive Input Power Example (with LIM Module)
MAIN VAC
Three-phase
Input Power
230V Control Power
2090-XXLF-TC
xxx
AC Line Filter
(optional component)
2094-AL
xx
S
Line Interface Module
(optional component)
I/O Connections
To Input Sensors
and Control String
2093-ASP06
Shunt Module
(optional component)
2093-PRF Slot Filler Module
(required to fill any unused slots)
2093-K2CK-COMBO
Low-profile Connector Kit
(optional component)
2093-AM
xx
Axis Modules (4)
2093-AC05-MP
x
Integrated Axis Module
Power Rail
2093-PRS
x
Input
Fusing
Summary of Contents for Allen-Bradley Kinetix 2000
Page 1: ...Kinetix 2000 Multi axis Servo Drives to Kinetix 5500 Servo Drives Migration Guide...
Page 6: ...6 Rockwell Automation Publication 2093 AP001A EN P May 2014 Table of Contents...
Page 12: ...12 Rockwell Automation Publication 2093 AP001A EN P May 2014 Preface Notes...
Page 62: ...62 Rockwell Automation Publication 2093 AP001A EN P May 2014 Appendix C Specifications Notes...
Page 75: ......