(217) 352-9330
|
[email protected]
artisantg.com
Find the
Rockwell / Allen-Bradley 6185-AAZAAZZ
at our website:
Click HERE
Page 1: ...tilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In stock...
Page 2: ...Economy Line Industrial Flat Panel Monitors Bulletin 6185 H 6185 J and 6185 K Installation and User Manual Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 3: ...ings 26 Verifying Fine Settings 26 Verifying Horizontal and Vertical Positions 27 Setting Brightness and Contrast 27 OSD Menu Reference 28 Performing Routine Maintenance 30 Cleaning 30 Replacing a Lin...
Page 4: ...d diagrams in this manual are included solely for illustrative purposes Because of the many variables and requirements associated with any particular installation Rockwell Automation cannot assume res...
Page 5: ...manual supports the following models 6185 H 15 0 Panel Mount 6185 J 17 0 Panel Mount 6185 K 17 0 Rack Mount Note If you want to mount your 15 monitor into a 19 rack you can use the optional rack adapt...
Page 6: ...1024x768 display Video formats supported from 640x480 to 1024x768 Fast response time 25 msec 120 H 100 V viewing angle Rack mount adapter brackets EIA 19 8U option Capabilities specific to the 6185 J...
Page 7: ...r ScreenSet monitor setup utility Package of mounting hardware AC power cord Video cable This user manual A monitor with a touchscreen option ships with these additional items Supporting software and...
Page 8: ...Option Option Letter Category Description H 6185 15 0 Panel Mount J 6185 17 0 Panel Mount 2 Monitor Size K 6185 17 0 Rack Mount 9U 3 Front Panel Type C Plastic Front Panel C Resistive Antiglare Touch...
Page 9: ...ucted Ensure that the ambient air temperature will not exceed the specified maximum temperature You may need a user supplied fan heat exchanger or air conditioner to meet this condition in some instal...
Page 10: ...these limits In very dry environments static charges build up very readily Proper grounding of the equipment through the AC power cord can help reduce the likelihood of static discharges which may ca...
Page 11: ...d by the panel in which it is installed Figure 5 Generic Panel Mount Diagram Note Your monitor may differ from the above graphic Tools Needed for Panel Mount Installation In addition to the tools requ...
Page 12: ...m depth of 3 0 in 76mm is sufficient Take precautions so that metal cuttings do not enter any components that are already installed in the panel Supporting panels should be at least 14 gauge to ensure...
Page 13: ...and washers supplied with the monitor around the perimeter of the monitor Extra lock nuts and washers are provided Note Use 10 32 or M5 self locking nuts for mounting ATTENTION You must apply nuts an...
Page 14: ...ollowing precautions when installing this unit in a rack The cabinet must be tall enough to accommodate the monitor s panel height eight rack units 14 00 356 mm for the 6185 H 15 panel mount with adap...
Page 15: ...ack cabinet can be of two types Wide rails have holes spaced 0 5 12 7 mm and 1 25 31 8 mm on centers in a repeating pattern Wide rails are prevalent in Europe Universal rails have holes spaced 0 5 12...
Page 16: ...host computer serial port for touchscreen Connecting to power IEC connector In the figure on the left the gray shaded areas represent where you are now in the general process to install connect and a...
Page 17: ...ote You can use longer cables up to approximately 75 feet in some cases provided they are properly constructed 2 Connect the other end to the output of any IBM compatible VGA adapter or other video ge...
Page 18: ...rial Interface on page 41 for additional details on the installation and operation of the touchscreen To connect the touchscreen 1 For units with the touchscreen option make sure you have the serial c...
Page 19: ...nnect the external power supply cable to the 12 VDC power input connector on the monitor Important If you need an extra cable restraint Rockwell Automation provides a lance in the sheet metal so you c...
Page 20: ...to disable the keypad The left position keeps the keypad enabled 3 Replace the plug when you are finished Figure 10 6185 Economy Line Keypad Disable Switch If the keypad is disabled and a key is press...
Page 21: ...Opens the OSD and sub menus Selects the highlighted function Exit Exits the OSD Selects the Video signal A or B while the OSD is off 6185 J and 6185 K only Auto Starts the Auto Video Adjustment functi...
Page 22: ...ally The possible settings are Plug and Play Monitor 6185 H 6185 J and 6185 K monitors with Plug and Play enabled system Super VGA 1024x768 6185 H manual setting Super VGA 1280x1024 6185 J and 6185 K...
Page 23: ...tor types 9 Click Show all Devices button 10 Verify Manufacturer Standard monitor types 11 Verify Models Plug and Play Monitor Super VGA 1024x768 Super VGA 1280x1024 4 Click Advance Properties button...
Page 24: ...b High color 16 bit color 2 6 Mb True Color 24 bit color 4 Mb Note The 6185 H displays up to 256k colors 18 bit color Because most workstations only support 8 bit 16 bit or 24 bit color you must opera...
Page 25: ...justment display appears Figure 12 Auto Adjustment Display For most users with the touch of one button the AUTO adjustment feature quickly and accurately adjusts the monitor Note A computer switches t...
Page 26: ...ove between the function icons As you move from one function to the other the function menu changes to represent the correct icon To activate the highlighted function press the MENU button Use the and...
Page 27: ...esolution different than the monitor the left side border on the setup screen should be as far left as possible while still being visible Refer to Check Operating Resolution on page 22 Note The left s...
Page 28: ...en are visible These adjustments will vary depending on your lighting conditions Perform these adjustments under the normal operating lighting conditions 1 Adjust the Brightness control as high as pos...
Page 29: ...erference Try the Fine adjustment first If you are not satisfied use the Coarse adjustment and then use the Fine again These functions may change the width of the display image Use the horizontal func...
Page 30: ...solution Normal uses the normal size viewing area for the current signal Expanded 1 expands the viewing area to the full width of the monitor screen Expanded 2 extends the viewing area both horizontal...
Page 31: ...screen to stand dry ATTENTION You can use alcoholic or ammoniac cleaners to clean the polycarbonate shield or a touchscreen However use only one or the other at all times A residue mixture can cause a...
Page 32: ...monitor If the monitor is functioning properly you will see a white box with a red border that reads Check Signal Cable This is the self test box Three smaller boxes red green and blue appear inside...
Page 33: ...on or installing an AC isolation transformer Picture bounces or has wavy oscillations Picture has blurry streaks or ghosting to the right of objects on the screen Check the video cable connection betw...
Page 34: ...monitor is saving your changes to the OSD The power indicator blinks amber The monitor is using its power management Green and Amber LEDs blink back and forth when keypad is pressed Monitor keypad loc...
Page 35: ...Product technical training Warranty support Support service agreements Refer to the Rockwell Automation Allen Bradley Internet site at http www ab com for local contact information Technical Product...
Page 36: ...e panels The rack adapter option is Accessory option R Installing Rack Adapter Brackets on a 6185 H Monitor 1 Carefully remove the monitor from its packaging 2 Locate four mounting studs on each side...
Page 37: ...or Dimensions This section shows the dimensions of the monitors Use this information to ensure you have adequate space to install the unit and route cables Units are in mm inches Figure 19 6185 H Pane...
Page 38: ...ns Front Panel Dimensions W1 x H1 x D1 17 25in x 14 0in x 0 3in 438mm x 355mm x 7mm Figure 21 6185 H Rear Chassis Dimensions Rear Chassis Dimensions W2 x H2 x D2 15 2in x 12 3in x 2 4in 386mm x 313mm...
Page 39: ...onitors Publication 6185 UM003C EN P Figure 22 6185 J Panel Mounting Cutout 6185 J 17 Panel Mount 6185 J 17 Panel Mount Dimensions Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SO...
Page 40: ...ns Front Panel Dimensions W1 x H1 x D1 19 0in x 15 7in x 0 3in 483mm x 399mm x 7mm Figure 24 6185 J Rear Chassis Dimensions Rear Chassis Dimensions W2 x H2 x D2 16 9in x 13 8in x 2 47in 429mm x 351mm...
Page 41: ...ensions W1 x H1 x D1 19 0in x 15 7in x 1 75in 483mm x 399mm x 44mm Figure 26 6185 J Rear Chassis Dimensions Rear Chassis Dimensions W2 x H2 x D2 16 9in x 13 8in x 2 47in 429mm x 351mm x 63mm 6185 K 17...
Page 42: ...2 C serial port on the host computer Because the touch controller obtains power from the monitor s power supply no external touch power connections are necessary Software supplied with the touchscreen...
Page 43: ...Installing the Touchscreen Driver Software To install the touchscreen driver software correctly obtain the following information about the host hardware The COM port in use for the touchscreen Ensure...
Page 44: ...nter these addresses in your Internet browser www elotouch com for resistive AccuTouch touchscreens Performing a Calibration After installing the driver software follow the instructions in the touchsc...
Page 45: ...e female connector Figure 27 HD 15 Video Connector The following table provides the pin numbers and corresponding pin assignments for the HD 15 video connector with the DDC2B capability Table H Standa...
Page 46: ...reen overlay option will reduce luminance Contrast Ratio typical 250 1 200 1 Response Time 25 msec typical 40 msec typical Video 6185 H 6185 J and 6185 K Supported Standards 720x400 at 70Hz VGA text 6...
Page 47: ...g 1 2 sine 11 msec Non Operating Shock 20g 1 2 sine 11 msec Operating Vibration 0 006 in p p 10 57 Hz sine 1 0g peak 57 640 Hz sine Non Operating Vibration 0 006 in p p 10 57 Hz sine 1 0g peak 57 640...
Page 48: ...ponent C UL 950 Recognized Component UL Listed when mounted in appropriate enclosure LVD 73 23 EEC EN 60950 per UL 1950 3rd ed without D3 dev EMC 89 336 EEC Emissions Immunity EN 50081 2 EN 50082 2 FC...
Page 49: ...of International Business Machines Corporation PC AT is a trademark of International Business Machines Corporation Microsoft is a registered trademark of Microsoft Corporation Microsoft Windows is a...
Page 50: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...