Environment and Enclosure Information

Review the information on enclosures and environments before installing the monitor.

European Union Directive Compliance

This monitor meets the European Union Directive requirements when installed within the 
European Union or EEA regions and have the CE mark. A copy of the Declaration of Conformity 
(DoC) is available at 

http://www.rockwellautomation.com/products/certification/ce/index.html

.

ATTENTION: Environment and Enclosure

This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage 
Category II applications (as defined in IEC publication 60664-1), at altitudes up to 2000 m (6561 ft) 
without derating.

This equipment is considered Group 1, Class A industrial equipment according to IEC/CISPR 11. Without 
appropriate precautions, there may be difficulties with electromagnetic compatibility in residential and 
other environments due to conducted and radiated disturbances.

UL listed equipment need not be mounted inside another enclosure if NEMA Type and IEC ratings 
are not required, but the mounting method must limit the tilt of the monitor to 30° from vertical. 
Examples include articulated arm, table-top stand, wall mount or other means having sufficient 
mechanical stability and which is secured to the mounting surface. Monitors that are not rack 
mounted ship with a gasketed bezel to meet specified NEMA Type, UL, and IEC ratings only when 
mounted in an enclosure with equivalent ratings. Subsequent sections of this publication may 
contain additional information regarding specific enclosure type ratings that are required to 
comply with certain product safety certifications.

In addition to this publication, see the following:

Industrial Automation Wiring and Grounding Guidelines, publication 

1770-4.1

, for additional 

installation requirements

NEMA Standard 250 and IEC 60529, as applicable, for explanations of the degrees of protection 
provided by enclosures

ATTENTION: 

This monitor is intended to operate in an industrial or control room environment, 

which uses some form of power isolation from the public low-voltage mains. Some computer 
configurations may not comply with the EN 61000-3-2 Harmonic Emissions standard as specified 
by the EMC Directive of the European Union. Obtain permission from the local power authority 
before connecting any computer configuration that draws more than 75 W of AC power directly 
from the public mains.

Summary of Contents for Allen-Bradley 6176M-15VN

Page 1: ...panel or rack This document does not provide information on monitor configuration or setup Topic Page Important User Information 2 Environment and Enclosure Information 3 European Union Directive Com...

Page 2: ...nstallation Rockwell Automation Inc cannotassume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by RockwellAutomation Inc with respect to...

Page 3: ...hod must limit thetilt of the monitor to 30 from vertical Examples include articulated arm table top stand wall mount or other means having sufficient mechanical stability and which is secured to the...

Page 4: ...g cartons to provide adequate protection for a monitor returned for service PartsList The monitors are shipped with these items Industrial Monitors and Accessories CD that contains device drivers Inst...

Page 5: ...e monitor helps to reduce static discharges which may cause shocks and damage electronic components The enclosure or cover must remain in place at all times during operation The cover provides protect...

Page 6: ...for 1950M monitors VESA mount Review each mounting type and monitor dimensions before installation PanelMounting The panel mount monitors are installed directly into a panel with mounting clips The nu...

Page 7: ...y installed in the panel Supporting panels must be at least 14 gauge to be sure of proper sealing against water and dust and to provide proper support The mounting hardware supplied accommodates panel...

Page 8: ...attach cables 3 Verify that the sealing gasket is properly positioned on the monitor This gasket forms a compression type seal Do not use sealing compounds 4 Place the monitor in the panel cutout 5 S...

Page 9: ...rances Make sure there is adequate space behind the rack panel Allow minimum clearances for cables and airflow See Mounting Clearances on page 7 ATTENTION Tighten the mounting clips to the specified t...

Page 10: ...ps to a torque of 1 1 Nm 10 lb in TIP For ease of installation make sure two or more people help to install the monitor ATTENTION The mounting rails that run vertically along the inside edges of the f...

Page 11: ...VESA FPMPMI 100 mm 3 94 in standards The mounting location must provide adequate clearance for positioning and moving the adjustable unit and for routing cables MountingtheMonitoronaBenchorTabletop F...

Page 12: ...n Publication 6176M IN001E EN P August 2012 MonitorDimensions Dimensions for the panel mount and VESA mount monitors are expressed in millimeters inches 1550M Panel Mount 1550M VESA Mount 50 0 2 0 410...

Page 13: ...Industrial Standard Monitors 13 Rockwell Automation Publication 6176M IN001E EN P August 2012 1750M Panel Mount 1750M VESA Mount 53 0 2 1 452 0 17 8 356 0 14 0 53 0 2 1 421 0 16 6 326 5 12 9...

Page 14: ...14 Industrial Standard Monitors Rockwell Automation Publication 6176M IN001E EN P August 2012 1950M Panel Mount 1950M VESA Mount 58 0 2 3 482 6 19 0 399 3 15 7 58 0 2 3 444 0 17 5 357 0 14 1...

Page 15: ...on computer for the optional touchscreen interface USB port on computer for the optional touchscreen interface USB hub device ports for connecting peripheral devices Power DC input connector must be...

Page 16: ...he digital video cable to the female DVI video input connector on the monitor 2 Connect the other cable end to the output of any digital DVI video source Cat No Description 6189V VGACBL2 Analog video...

Page 17: ...e configured using either the serial RS 232 connection or USB connection ConnectingtheOptionalSerialRS 232TouchscreenInterface The RS 232 DB9 female D shell connector on the bottom side of the monitor...

Page 18: ...mingaCalibration After installing the driver follow the calibration instructions in the touchscreen documentation Following installation of the touchscreen driver and calibration the touchscreen is re...

Page 19: ...e that supplies the computer Follow these steps to connect power to the monitor 1 Connect the supplied AC power adapter cable to the power input connector on the monitor 1 2 Secure this connection by...

Page 20: ...e monitor and place it in its original packing material ATTENTION The backlight assembly in this monitor contains mercury At the end of its life this monitor should be collected separately from any un...

Page 21: ...9 mm 9 0 x 12 0 in 338 x 270 mm 13 3 x 10 7 in 377 x 302 mm 14 8 x 11 9 in Resolution WxH approx 1024x768 nativemode 16 7M colors 1280 x 1024 native mode 16 7Mcolors Luminance typical 350 cd m2 Nits 3...

Page 22: ...ty 10 90 noncondensing Shock Operating Nonoperating 15 g 1 2 sine 11 ms 20 g 1 2 sine 11 ms Shock Operating Nonoperating 15 g 1 2 sine 11 ms 20 g 1 2 sine 11 ms Vibration Operating Nonoperating 0 015...

Page 23: ...ource Description Industrial Standard Monitors User Manual publication 6176M UM001 Provides information on how to install configure and troubleshoot 6176M industrial monitors Industrial Monitors Cutou...

Page 24: ...a special Customer Support number for initial help in getting your product up and running NewProductSatisfactionReturn Rockwell Automation tests all of its products to ensure that they are fully opera...

Reviews: