Rockwell Automation Publication 48CR-UM001A-EN-P - November 2019
129
Parameter Overview
Chapter 7
– Read Rate
Percentage read rate is initiated upon release of the button in this
position.
– Calibrate
Causes the device to adjust photometry and optical settings (if
applicable) for optimal decoding performance.
– Save for Power-on
User parameters are saved and hardware reset occurs upon release of the
button.
– Load New Master
The decoded symbol read is loaded into the first position of the master
database upon release of the button.
– Target System
Targeting pattern is turned OFF if the target pattern is OFF and turned
ON if the target pattern is ON.
– Barcode Configuration
A way of programming the device by using ECC 200 Data Matrix
symbols when this mode has been entered.
Output 1 and 2 Parameters
Figure 97 - AOP
Figure 98 - WebConnect
Output On
This option provides discrete signaling to host software to control external
devices such as PLCs and relays. It is useful for routing, sorting, and helping
prevent mispackaging and misrouting.
It sets the discrete output functions for specific user-selected conditions. Allows
you to determine when an output (or outputs) is activated.
AOP View
WebConnect View
IMPORTANT
Output 1 Parameters are shown as an example in
Output 2 Parameters have the same options.