2
Rockwell Automation Publication 42G-TD001C-EN-P - June 2022
Series 9000 Photoelectric Sensors Specifications Technical Data
Specifications
Optical and Response Time Characteristics
Table 1 - All Models
Attribute
Value
Certifications
cULus Listed, CSA Certified, and CE Marked for all applicable
directives
Shock
30 g with 1 ms pulse duration, meets or exceeds IEC 60947-5-2
Vibration
10…55 Hz, 1 mm amplitude, meets or exceeds IEC 60947-5-2
Environmental
Enclosure type rating
IP69K, IP67 with 1200 psi; NEMA 3, 4X, 6P, 12, 13; ECOLAB rated
Relative humidity
5…95%
Ambient light immunity
Incandescent light 5000 lux
Electrical
Operating voltage
See
Mechanical
Material
• Housing: Valox®
• Lens: Acrylic
Connection type
See
Table 2 - Standard Models
Attribute
Value
Environmental
Operating temperature
-34…+70 °C (-29…+158 °F)
User Interface
Status indicator
See
.
Electrical
Current consumption
30 mA max
Protection type
• Short circuit
• Reverse polarity
• False pulse
• Overload
Outputs
Output type
See
Output function
Selectable light or dark operate
Load current
• 250 mA at 30V DC (all models except 42GLP and 42GSP)
• 2 A at 132V AC and 1 A at 264V AC (SPDT relay models)
• 300 mA at 264V AC (MOSFET models)
Table 3 - Laser Models
Attribute
Value
Environmental
Operating temperature
-10…+50 °C (-14…+122 °F)
Electrical
Current consumption,
max
• DC models: 45 mA
• AC/DC models: 10 mA
• AC models: 70 mA
Protection type
• Overload and short circuit (DC models)
• Reverse polarity
• False pulse
Outputs
Output type
See
Output function
Selectable light or dark operate
Leakage current, max
10 µA (DC models)
Table 4 - Optical and Response Time Characteristics—Standard and Intrinsically Safe Transmitted Beam Models
Attribute
Sensing Mode
Retroreflective
Polarized
Retroreflective
Diffuse
Transmitted Beam
Small Aperture
Fiber Optic
Large Aperture
Fiber Optic
Field of view
1.5°
3.5° for 1.5 m (4.92 ft)
6.5° for 3 m (9.8 ft) and 4 m (13 ft) range
1.5°
Depends on fiber-optic cable
Light source
Visible red 660 nm
Infrared 880 nm
Response time
2 ms (DC), SPDT EM relay (15 ms), 2 ms (MOSFET AC/DC)
Table 5 - Optical and Response Time Characteristics—Laser Models
Attribute
Sensing Mode
Polarized Retroreflective
Diffuse
Spot size
20 x 25 mm (0.98 in.) at 40 m (131.23 ft)
2 x 3.5 mm (0.14 in.) at 800 nm
Response time
0.5 ms