116
Rockwell Automation Publication 2094-UM001D-EN-P - May 2010
Chapter 5
Connecting the Kinetix 6000 Drive System
Connect Panel-mounted Breakout Board Kits
The 2090-UXBK-D15
xx
panel-mounted breakout board kit includes a DIN-rail
breakout board and cable. The cable connects between the breakout board and
the motor feedback (MF) connector. Wires from your flying-lead motor
feedback cable connect to the terminals.
Figure 61 - IAM/AM Module (MF connector)
2090-UXBC-D15
xx
Breakout Cable
2090-UXBB-D15
Panel-mounted Breakout Board
Wire Terminations
Motor Feedback (MF) Connector
Kinetix 6000, Front View
(IAM module is shown)
Kinetix 6000, Side View
(IAM module is shown)
Refer to CN2 Motor Feedback Breakout Board
Installation Instructions, publication
for connector breakout board specifications.
IMPORTANT
The panel-mounted breakout board kit (2090-UXBK-D15
xx
) is not
compatible with 1326-CCUT-L
-xxx
cable.